R5905769 /04
ICMP/ICMP-X HDD
12
Type of HDD swap
On ICMP
On ICMP-X
Set of 3 HDDs with content
reused from an ICMP with
GEN1 storage controller.
On an ICMP with GEN1 storage
controller:
•
Content is preserved but
certificates (KDM) need to be re-
ingested.
On an ICMP with GEN2 storage
controller:
•
All content will be lost.
•
Only usable after RAID
initiali restart (content
can then be ingested
immediately).
•
All content will be lost.
•
Only usable after RAID
initiali restart (content
can then be ingested
immediately).
Set of 3 HDDs with content
reused from an ICMP-X.
•
Unit is equipped with an GEN1
storage controller (default
configuration):
•
All content will be lost.
•
RAID initialization needs to be
perform with Communicator.
•
Unit has been upgraded with a
GEN2 storage controller (+ ICMP
software 1.4.2 or higher is
installed):
•
Content is preserved but
certificates (KDM) need to be
re-ingested.
•
Content is preserved but
certificates (KDM) need to be re-
ingested.
1.4 HDD status LEDs
HDD status LEDs
5
4
Image 1-5
4
HDD I/O LED
5
RAID LED
Status LEDs on ICMP
HDD I/O
RAID
HDD Status
Off
Off
HDD idle / disk in RAID OK.
Blinking green
Off
HDD I/O activity / disk in RAID OK.
Blinking green
Slow blinking
red
HDD disks not (yet) initialized (not supported on ICMP with GEN1 storage
controller).