background image

R5905769 /04

ICMP/ICMP-X HDD

10

CAUTION:

The loss of one disk causes no serious consequences on the ICMP. But action must be

taken quickly because the loss of a second disk will make the RAID system broken. The main cause
of the total loss of RAID is due in most cases to the loss of the second disk while the first has not
been rebuilt!

A failed drive should be replaced as soon as possible.

About

RAID recovery

process

The restoration from degraded to normal condition of the RAID 5 system is done automatically. When the
RAID controller detects a new HDD to replace the failed disk the recovery procedure starts automatically.

CAUTION:

The automatic process does not work if more than one disk is lost. In that case the RAID

must be completely initialized again!

About RAID broken

When more than one HDD is out of order, the RAID is considered as 'broken' and the content is lost. The failed
HDDs must be changed and a new RAID must be created.

Exchange or re-use of a disk set

It's possible to have several sets of disks with one ICMP or to reuse a complete set of disks coming from
another projector with ICMP.

How to exchange:

Exchange of HDD set between two ICMPs with the same storage controller:

It is sufficient to insert the three HDDs, from a valid RAID array, and let the system explore the new RAID.
The mounting order of the HDDs and the HDD slots do not matter. Of course, when using HDDs from
another ICMP it is necessary to retrieve from the content distributor the KDMs corresponding to the content
and the new ICMP.

Exchange of HDD set between two ICMPs with a different storage controller:

After inserting the three HDDs it is necessary to perform a manual RAID initialization with (Web)
Communicator, the Barco projectors configuration software. The

RAID initialization

command (e.g. in Web

Communicator:

Maintenance

>

Raid Storage

) erases any data present on the HDDs and the old content

will be lost. This will only take a short while and after this process, the projector will reboot. You can start
immediately after booting with the ingest of your content.

The problem of non-compatibility between the two generations of storage controllers is also
encountered when installing a new set of hard drives on an ICMP-X. The HDD spare part kits
provided by Barco are configured by default to work with a GEN1 storage controller and it is
necessary to perform a manual RAID initialization when they are deployed on a GEN2 storage
controller.

Label the HDDs with the initialization type (GEN1 or GEN2) to make it visible for which type of
storage controller the disks can be used without requiring a re-initialization and lost of content

HDD storage capacity

Make sure that all HDDs in the ICMP HDD set have the same storage capacity. See label on top of the HDD to
know the storage capacity.

HDD storage

The maximum recommended storage period for the drive in a non-operational environment is 90 days. Drives
should be stored in the original unopened shipping packaging whenever possible. Once the drive is removed
from the original packaging the recommended maximum period between drive operation cycles is 30 days.
During any storage period the drive non-operational temperature, humidity, wet bulb, atmospheric conditions,
shock, vibration, magnetic and electrical field specifications should be followed.

HDD(s) on ICMP

Summary of Contents for ICMP

Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual ICMP ICMP X HDD ...

Page 2: ...Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com ...

Page 3: ...from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources For more information about recycling of this product please contact your local city office or your municipal waste disposal service For details please visit the Barco website at http www barco com AboutBarco weee EMC notices EN55032 CISPR32 Class A MME MultiMedia Equipment Warning This equ...

Page 4: ...vided by Barco being a component of the system or independent service will be deemed invalid provided the damage is not proven to be attributed to the absence of properties guaranteed in writing or due to the intent or gross negligence or part of Barco If the purchaser or a third party carries out modifications or repairs on goods delivered by Barco or if the goods are handled incorrectly in parti...

Page 5: ...P 7 1 1 General 8 1 2 ICMP HDD 9 1 3 What are the possible HDD swaps 11 1 4 HDD status LEDs 12 1 5 Removing a HDD from the ICMP 14 1 6 Installing a HDD into the ICMP 15 R5905769 04 ICMP ICMP X HDD 5 Table of contents ...

Page 6: ...R5905769 04 ICMP ICMP X HDD 6 ...

Page 7: ...e only one HDD is replaced RAID degraded mode the ICMP automatically starts with the RAID recovery process after the malfunction HDD is replaced The red LED of the HDD which has to be rebuilt is blinking Rebuild process takes about 3 to 4 hours for 1TB HDD and could takes about 13 to 14 hours for 4TB HDD Once the RAID is completed the red LED turns off CAUTION It s strongly recommended to complete...

Page 8: ...inema projector refer to the manual of the projector which is also available on the Barco website GEN1 and GEN2 storage controller The ICMP X is equipped with a GEN2 storage controller while the legacy ICMP has an GEN1 storage controller The GEN2 storage controller supports SSD and uses another disk initialization type This implies that HDDs initialized for the legacy ICMP with GEN1 storage contro...

Page 9: ...the ICMP are set up in a RAID 5 configuration This storage technique that combines multiple HDD components into a logical unit manages enough redundancy information to continue to operate properly after the loss of one HDD Image 1 4 CAUTION A RAID 5 configuration with three HDDs allows a maximum loss of one disk With the simultaneous loss of more than one HDDs data is lost and the RAID must be com...

Page 10: ... ICMPs with a different storage controller After inserting the three HDDs it is necessary to perform a manual RAID initialization with Web Communicator the Barco projectors configuration software The RAID initialization command e g in Web Communicator Maintenance Raid Storage erases any data present on the HDDs and the old content will be lost This will only take a short while and after this proce...

Page 11: ...ollowing table exposes all possible swaps available concerning HDDs on ICMP Replacing drives should always be done while the power is off Type of HDD swap On ICMP On ICMP X 1 HDD replaced Content is preserved ICMP automatically starts rebuild Process takes about 3 4 hours for 1TB HDD and could takes about 13 14 hours for 4TB HDD Content is preserved ICMP X automatically starts rebuild Process take...

Page 12: ...nt reused from an ICMP X Unit is equipped with an GEN1 storage controller default configuration All content will be lost RAID initialization needs to be perform with Communicator Unit has been upgraded with a GEN2 storage controller ICMP software 1 4 2 or higher is installed Content is preserved but certificates KDM need to be re ingested Content is preserved but certificates KDM need to be re ing...

Page 13: ...the ICMP page 15 Ensure to insert the HDD firmly 3 Switch on the power Result As soon the new HDD is detected by the ICMP the rebuild of the RAID is started Blinking red LED One disk failed red LED Error 10580 local storage not available Note The disk status Error code can be retrieved via the Web Commander See user guide of the Web Commander 1 Switch off the power 2 Replace the defect HDD with ap...

Page 14: ...main off Error 10580 local storage not available Note The disk status Error code can be retrieved via the Web Commander See user guide of the Web Commander 1 Switch off the power 2 Reseat all HDDs See procedure Removing a HDD from the ICMP page 14 and Installing a HDD into the ICMP page 15 Ensure to insert the HDDs firmly 3 If problem remains try RAID Initialize See user guide of the Web Communica...

Page 15: ...HDD from another ICMP HDD set CAUTION Always make sure that all HDDs in the ICMP HDD set have the same storage capacity See label on top of the HDD to know the storage capacity Re initialization or rebuild of RAID Installing or exchange one or several HDDs into ICMP has an impact on data presents on the already inserted drives RAID integrity depends on the type of HDD swap Refer to the chapter Wha...

Page 16: ...ds the right Image 1 11 5 Switch on the projector In case you replace one HDD e g degraded mode the ICMP automatically starts with the RAID recovery process The red LED of the HDD which has to be rebuilt is blinking This process takes about 200 GB per hour Once the RAID is completed the red LED turns off CAUTION It s strongly recommended to complete the RAID recovery process prior to starting a sh...

Page 17: ...R5905769 04 ICMP ICMP X HDD 17 HDD s on ICMP ...

Page 18: ...Barco NV Beneluxpark 21 8500 Kortrijk Belgium Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5905769 04 2019 10 21 ...

Reviews: