Page 5-1

5 TECHNICAL SPECIFICATIONS

HDM 5049 PLUS FEATURES

 

User-friendly keyboard and OSD

 

AKB color stability circuit

 

Orbiting pixel shift system

 

Automatic Color Alignment

 

Password protection

 

19” rack-mountable

 Programmable 

quick 

degauss

INPUT CONFIGURATION

RGB Input

 

Nominal level: 0.7 Vpp ± 3 dB

 BNC 

connectors

 

75 ohm termination switch

Sync Input

 

Nominal level: 2 Vpp,

 

Min. 1 Vpp, max 5 Vpp

 

Composite or separate H/V sync

 BNC 

connectors

 390 

ohm

Communication Input / Output

 

Female Sub-D 9-pin connector (RS-232)
for Thoma / Philips Color Analyzer

VIDEO PERFORMANCE RGB DRIVE

 

RBG bandwidth: 135 MHz typical

 

Pulse rise and fall time: typical 3.5 ns

 

Black level stability: 0.5% (0-100% APL)

SCANNING SYSTEMS

Horizontal scanning

 Multisync 

microprocessor 

controlled

 

Frequency range: 30 - 82 kHz

Vertical scanning

 

Frequency range: 48 – 150 Hz

 

Minimum blanking: 420 

µ

s

Factory-stored Modes

 

1080L x 1920P, 60 Hz Interlaced
(SMPTE 274M)

 

1035L x 1920P, 60 Hz Interlaced
(SMPTE 240M-260M)

 

720L x 1280P, 60 Hz Non-interlaced
(SMPTE 296M)

 

480L x 704P, 60 Hz Non-interlaced
(SMPTE 293M)

 

V

IVALDI 

525 lines / 60Hz 4 Pictures Mode

 

V

IVALDI

 525 lines / 60Hz 1 Picture Full

Screen Mode

VISUAL PERFORMANCE

Picture tube

 

Dot-In-Line, diagonal: 19” (17” visible)

 

Dot pitch: 0.26 mm

 

Transparency: 46%

 

Phosphor type: P22, rare-earth (red),
sulfide (blue and green)

 

Max. convergence error:
Zone A: 0.3 mm, Zone B: 0.4 mm.

Resolution

 

Addressable pixels: 1240

 Focus 

control: 

DAF 

system

Geometry

 

Maximum error: 1%

CONTROL

 

OSD (On Screen Display) menus

 

Direct access buttons for contrast,
brightness, Degauss, Power On/Off
(standby)

 Menu 

push-buttons

 

Power switch at rear side

POWER SUPPLY

 

Auto-selection: 90–135 / 195–265 V AC

 

Power consumption: 120 W nominal

 

Frequency limits: 45 – 65 Hz

ENVIRONMENTAL SPECIFICATIONS

 Temperature 

range:

Operation: 0 / +45 °C
Storage: -20 / +65 °C

 

Altitude: 10,000 ft / 3000 m

 

Humidity (relative): 95% maximum, non-
condensing

MAGNETIC IMMUNITY

 

Automatic Quick Degauss system (minimum
interval: 10 s)

 

Vertical and Axial White Uniformity
correction

PHYSICAL SPECIFICATIONS

 

Number of 19” rack units: 8

 

Dimensions (without handles):
Width: 438 mm / 17.24 inch
Height: 354 mm / 13.97 inch
Depth: 483 mm / 19.01 inch
Weight: 25 kg / 55.12 lb.

Technical specifications are subject to change without prior notice.

Summary of Contents for HDM 5049 PLUS

Page 1: ...SER S MANUAL Serial Number Edition May 27 th 1999 Part Number V598958 01 BARCO N V Communication Systems Th Sevenslaan 106 B 8500 Kortrijk Belgium Tel 32 56 233 211 Fax 32 56 233 461 E mail support bc...

Page 2: ......

Page 3: ...Conditions 3 3 4 OPERATION AND ADJUSTMENT 4 1 4 1 USING THE KEYBOARD 4 1 4 2 MAIN MENU 4 2 4 3 STATUS MENU 4 2 4 4 SETTINGS MENU 4 2 4 4 1 Modename 4 3 4 4 2 AKB 4 3 4 4 3 Orbiter 4 3 4 4 4 Degauss ra...

Page 4: ......

Page 5: ...communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 1 2 Powe...

Page 6: ......

Page 7: ...dard features are 16 9 aspect ratio 19 picture tube 17 visible Occupies only 8 RU space in a 19 rack Superfine dot pitch of 0 26 mm Small spot size over the entire screen Automatically adjusts to diff...

Page 8: ......

Page 9: ...d be mounted in a 19 rack Four retaining screws in the handles keep the monitor in place Do not cover or block the ventilation openings in the cover 3 3 Signal Connection SERVICE 75E R G B HS CS VS PO...

Page 10: ...Lines Frame Lines 525 750 1125 1125 Active Lines Field Lines 517 5 540 Active Field Time ms 15 33 16 Blanking Lines Field Lines 45 22 5 Blanking Time Field ms 1 33 0 67 Total Lines Field Lines 562 5 5...

Page 11: ...ition 9 9 OK 10 Clamping problem Remove HS condition 7 11 No vertical sync due to addition of two opposite pulses Clamping problem Remove VS to solve Vert Sync problem and Remove HS because no vertica...

Page 12: ......

Page 13: ...Use to reveal remove the Contrast setting Adjust with or Press both keys simultaneously to return to the calibrated value Brightness Use to reveal remove the Brightness setting Adjust with or Press bo...

Page 14: ...nu Depending on the resolution of the input signal the middle part of this menu is split into two parts that are displayed alternately Press to leave the Status menu The menu disappears automatically...

Page 15: ...AKB On Off or Auto The AKB system guarantees color stability by changing the DC levels of the RGB cathode drive signals in order to keep the light output of the AKB measuring lines constant Note that...

Page 16: ...te level Press or to change the light output from 60 to 120 cd m nit in steps of 1 cd m This setting is also used during automatic color temperature alignment Leave the menu with 4 4 7 Change password...

Page 17: ...ait 10 seconds or press the password entrance menu reappears Select a submenu with or and press to enter Press to leave the Adjustments menu 4 5 1 Color Select manual or automatic color alignment with...

Page 18: ...PM 5639 01 kit or the combined PM 5639 02 and PM 5639 62 kits To align the HDM 5049 PLUS proceed as follows With Thoma Color Analyzer 1 Connect the Thoma TMF3 or TMF6 Color Analyzer to the Service co...

Page 19: ...ys following message Press to return to the Color menu If alignment failed the HDM 5049 PLUS displays following message Press to return to the Color menu The old alignment values are restored An align...

Page 20: ...ss to leave the Geometry menu If changes have been made you will be asked to save or to discard these changes Press to select yes or no then press Horizontal Size Horizontal Position Vertical Size Ver...

Page 21: ...of the earth s magnetic field The vertical component causes a horizontal deviation of the electron beam The compensation is a DC current through the degauss coils in the top and bottom of the monitor...

Page 22: ...In the Information Menu you can find the serial number the part number the software number and version and the time the monitor has been running since it left the factory Press to leave the menu The...

Page 23: ...rlaced SMPTE 296M 480L x 704P 60 Hz Non interlaced SMPTE 293M VIVALDI 525 lines 60Hz 4 Pictures Mode VIVALDI 525 lines 60Hz 1 Picture Full Screen Mode VISUAL PERFORMANCE Picture tube Dot In Line diago...

Reviews: