HDM 5049 PLUS Installation

HDM 5049 PLUS

Page 3-2

3.3.1  Factory-stored HDTV Modes

   System:

480L x

704P

60P

720L x

1280P

60P

1035L x

1920P

60I

1080L x

1920P

60I

Mode Name:

SMPTE293M
(483L x 720P)

SMPTE296M

SMPTE240M-
260M

SMPTE274M

Horizontal Timings:

Units

Horizontal Scan Frequency:

kHz

31,5

45

33,75

33,75

Total Line Time:

µs

31,75

22,22

29,63

29,63

Active Line Time:

µs

26,64

17,24

25,86

25,86

Horizontal Blanking:

µs

5,1

4,98

3,77

3,77

Horizontal Sync Width:

µs

2.33(*)

0.54(*)

0.6 (*)

0.6(*)

Horizontal Front Porch:

µs

0.63(*)

1.50(*)

1.2 (*)

1.2(*)

Horizontal Back Porch:

µs

2.15

2.95

1.99

1.99

Vertical Timings:

Units

Scan System:

I / P

P

P

I

I

Vertical Scan Frequency:

Hz

60

60

60

60

Active Lines /  Frame:

Lines

483

720

1035

1080

Active Frame Time:

ms

15,33

16

30,66

32

Blanking Lines / Frame:

Lines

42

30

90

45

Blanking Time Frame:

ms

1,33

0,67

2,66

1,34

Total Lines / Frame:

Lines

525

750

1125

1125

Active Lines / Field:

Lines

517,5

540

Active Field Time:

ms

15,33

16

Blanking Lines / Field:

Lines

45

22,5

Blanking Time / Field:

ms

1,33

0,67

Total Lines / Field:

Lines

562,5

562,5

Vertical Sync Width:

Lines

6

5

5

5

Vertical Front Porch:

Lines

6

5

2-2.5

2

Vertical Back Porch:

Lines

30

20

38-37.5

15

(*) Conversion from tri-level sync to bi-level sync

1035Lx1920P 60I is not stored as a separate mode, but the HDM 5049 PLUS displays this signal
type using the 1080Lx1920P 60I mode. The only difference is the number of active lines.

3.3.2  Vivaldi Modes

Two V

IVALDI 

Modes (only for 525 lines / 60 Hz) are factory-stored as well: 4 Pictures and 1 Picture

Full Screen.

When connected to a V

IVALDI

, you have to configure the V

IVALDI 

for positive

horizontal and vertical sync, no composite sync, no sync on green. Set the
V

IVALDI

 to 4/3 (positive vertical sync). The HDM 5049 PLUS is already

aligned for 16/9. Do not toggle between 4/3 and 16/9 on the V

IVALDI

, since

this changes the vertical sync polarity.

IMPORTANT!

Summary of Contents for HDM 5049 PLUS

Page 1: ...SER S MANUAL Serial Number Edition May 27 th 1999 Part Number V598958 01 BARCO N V Communication Systems Th Sevenslaan 106 B 8500 Kortrijk Belgium Tel 32 56 233 211 Fax 32 56 233 461 E mail support bc...

Page 2: ......

Page 3: ...Conditions 3 3 4 OPERATION AND ADJUSTMENT 4 1 4 1 USING THE KEYBOARD 4 1 4 2 MAIN MENU 4 2 4 3 STATUS MENU 4 2 4 4 SETTINGS MENU 4 2 4 4 1 Modename 4 3 4 4 2 AKB 4 3 4 4 3 Orbiter 4 3 4 4 4 Degauss ra...

Page 4: ......

Page 5: ...communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 1 2 Powe...

Page 6: ......

Page 7: ...dard features are 16 9 aspect ratio 19 picture tube 17 visible Occupies only 8 RU space in a 19 rack Superfine dot pitch of 0 26 mm Small spot size over the entire screen Automatically adjusts to diff...

Page 8: ......

Page 9: ...d be mounted in a 19 rack Four retaining screws in the handles keep the monitor in place Do not cover or block the ventilation openings in the cover 3 3 Signal Connection SERVICE 75E R G B HS CS VS PO...

Page 10: ...Lines Frame Lines 525 750 1125 1125 Active Lines Field Lines 517 5 540 Active Field Time ms 15 33 16 Blanking Lines Field Lines 45 22 5 Blanking Time Field ms 1 33 0 67 Total Lines Field Lines 562 5 5...

Page 11: ...ition 9 9 OK 10 Clamping problem Remove HS condition 7 11 No vertical sync due to addition of two opposite pulses Clamping problem Remove VS to solve Vert Sync problem and Remove HS because no vertica...

Page 12: ......

Page 13: ...Use to reveal remove the Contrast setting Adjust with or Press both keys simultaneously to return to the calibrated value Brightness Use to reveal remove the Brightness setting Adjust with or Press bo...

Page 14: ...nu Depending on the resolution of the input signal the middle part of this menu is split into two parts that are displayed alternately Press to leave the Status menu The menu disappears automatically...

Page 15: ...AKB On Off or Auto The AKB system guarantees color stability by changing the DC levels of the RGB cathode drive signals in order to keep the light output of the AKB measuring lines constant Note that...

Page 16: ...te level Press or to change the light output from 60 to 120 cd m nit in steps of 1 cd m This setting is also used during automatic color temperature alignment Leave the menu with 4 4 7 Change password...

Page 17: ...ait 10 seconds or press the password entrance menu reappears Select a submenu with or and press to enter Press to leave the Adjustments menu 4 5 1 Color Select manual or automatic color alignment with...

Page 18: ...PM 5639 01 kit or the combined PM 5639 02 and PM 5639 62 kits To align the HDM 5049 PLUS proceed as follows With Thoma Color Analyzer 1 Connect the Thoma TMF3 or TMF6 Color Analyzer to the Service co...

Page 19: ...ys following message Press to return to the Color menu If alignment failed the HDM 5049 PLUS displays following message Press to return to the Color menu The old alignment values are restored An align...

Page 20: ...ss to leave the Geometry menu If changes have been made you will be asked to save or to discard these changes Press to select yes or no then press Horizontal Size Horizontal Position Vertical Size Ver...

Page 21: ...of the earth s magnetic field The vertical component causes a horizontal deviation of the electron beam The compensation is a DC current through the degauss coils in the top and bottom of the monitor...

Page 22: ...In the Information Menu you can find the serial number the part number the software number and version and the time the monitor has been running since it left the factory Press to leave the menu The...

Page 23: ...rlaced SMPTE 296M 480L x 704P 60 Hz Non interlaced SMPTE 293M VIVALDI 525 lines 60Hz 4 Pictures Mode VIVALDI 525 lines 60Hz 1 Picture Full Screen Mode VISUAL PERFORMANCE Picture tube Dot In Line diago...

Reviews: