67
R5916677 /00
G50
6.4 UST lens support adjustment
About lens detection
G50 will detect the UST lens type while inserting the lens or reboot the projector. The image will automatically
flipped as default and the lens memory function will be automatically disabled.
For any type of projector, do not use the memory recall functionality.
Please check the projected image, if required; please do manually flip the image while choosing the
projection direction. Depending on your configuration, the lens memory function is automatically
disabled when used with unsupported lens.
Location of the adjustment screws
Before adjusting the lens, make sure that screws 1 to 4 on the adapter are not tightened, and that screws 5
and 6 are in mid position.
1
2
6
3
4
5
Image 6–21
How to adjust
1.
Start up the projector and display a test pattern.
Shift the UST lens to the target position.
Vertically lift the lens by hand to have the image as good as possible (reference A).
Tighten the vertical shifting screws 2 & 3 to secure this target position (reference B).
1
2
3
4
A
B
Image 6–22