background image

1. Safety

Label image

Label description

Label location

WARNING! DO NOT LOOK INTO THE LIGHT BEAM
NO DIRECT EYE EXPOSURE TO THE BEAN IS
PERMITTED

RG3 IEC EN 62471–5:2015

CLASS 1 IEC EN 60825–1:2014

HAZARD DISTANCE: CONSULT SAFETY MANUAL

COMPLIES WITH 21 CFR 1040 EXCEPT WITH
RESPECT TO THOSE CHARACTERISTICS
AUTHORIZED BY VARIANCE NUMBER 2014-V-0285
DATED APRIL 14, 2016 RISK GROUP 3 LIP IEC
62471:2016

警告!

看光束

眼睛勿直接接触可允

暴露的光束

(RG3 IEC EN 62471-5:2015 CLASS 1 IEC EN
60825-1:2014)

危害距离:

参考

安全手册

DANGER !

NE PAS REGARDER LE FAISCEAU EVITER TOUTE
EXPOSITION DIRECTE DES YEUX AU FAISCEAU

RG3 IEC EN 62471-5:2015

CLASS 1 IEC EN 60825-1:2014

DISTANCE DE SECURITE : CONSULTER LE MANUEL
DE SECURITE

Hazard RG3: not for household use symbol

1.4

High Brightness precautions: Hazard Distance (HD)

HD

Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the energy per surface
unit becomes lower than the applicable exposure limit on the cornea or on the skin. The light beam is considered (to
be) unsafe for exposure if the distance from a person to the light source is less than the HD.

Restriction Zone (RZ) based on the HD

The HD depends on the amount of lumens produced by the projector and the type of lens installed. See next chapter"HD in function
of modifying optics", page 9 
.

To protect untrained end users (as cinema visitors) the installation shall comply with the following installation requirements: Oper-
ators shall control access to the beam within the hazard distance or install the product at the height that will prevent spectators’
eyes from being in the hazard distance. Radiation levels in excess of the limits will not be permitted at any point less than 2.0 (SH
image 1-1) meters above any surface upon which persons other than operators, performers, or employees are permitted to stand
or less than 1,0 (SH image 1-1) meters lateral separation from any place where such persons are permitted to be. In non-cinema
environments where unrestrained behavior is reasonably foreseeable, the minimum separation height should be greater than or
equal to 3,0 m to prevent potential exposure, for example by an individual sitting on another individual’s shoulders, within the HD.

These values are minimum values and are based on the guidance provided in IEC 62471-5:2015 section 6.6.5.

The end user must understand the risk and apply protective measures based upon the hazard distance as indicated on the label and
in the user information. Installation method, barriers, detection system or other applicable control measure shall prevent hazardous
eye access to the radiation within the hazard distance.

6

R5906714 DP2K CLP SERIES 09/05/2016

Summary of Contents for DP2K CLP series

Page 1: ...DP2K CLP series Safety manual R5906714 01 09 05 2016 ...

Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 36 82 11 Fax 32 56 36 883 86 Support www barco com en support Visit us at the web www barco com Printed in Belgium ...

Page 3: ...cisely All local installation codes should be adhered to Notice on safety This equipment is built in accordance with the requirements of the international safety standards IEC60950 1 EN60950 1 UL60950 1 and CAN CSA C22 2 No 60950 1 which are the safety standards of information technology equipment including electrical business equipment These safety standards impose important requirements on the u...

Page 4: ... responsible for the location Why a restricted access location This is a RG3 product Based on international requirements no person in allowed to enter the projected beam within the zone between the projection lens and the related Hazard Distance HD This shall be physically impossible by creating sufficient separation height or by placing optional barriers Within the restricted area operator traini...

Page 5: ...rojector always take it to an authorized trained service person when service or repair work is required Do not use an accessory attachment which is not recommended by the manufacturer Lightning For added protection for this video product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect media and communication c...

Page 6: ...e projector eg during service always disconnect the power from the projector mains terminals and UPS INLET connector Use the disconnect device in the building installation to disconnect the power to the projector mains terminals and unplug the power cord at the UPS INLET connector if the UPS INLET is separately powered Do not place this equipment on an unstable cart stand or table The product may ...

Page 7: ...ot permitted to use the projector in another position See installation procedure for correct installation Special care for Laser Beams Special care should be used when DLP projectors are used in the same room as high power laser equipment Direct or indirect hitting of a laser beam on to the lens can severely damage the Digital Mirror DevicesTM in which case there is a loss of warranty Never place ...

Page 8: ...ns installed See next chapter HD in function of modifying optics page 9 To protect untrained end users as cinema visitors the installation shall comply with the following installation requirements Oper ators shall control access to the beam within the hazard distance or install the product at the height that will prevent spectators eyes from being in the hazard distance Radiation levels in excess ...

Page 9: ...s defined as 1 0m 3 3 ft by the FDA CDRH RA TH PR RZ HD SW 1m SW SW SW HD SH RA TH RZ SH B TOP VIEW A SIDE VIEW Image 1 1 A Side view B Top view RA Restricted Access location boot area of projector PR Projector TH Theater RZ Restriction Zone in the theater SH Separation Height SW Separation Width Based on national requirements no person is allowed to enter the projected beam within the zone betwee...

Page 10: ...flection the distance that has to be kept restrictive related to the reflected light from the rear projection screen HDdiffuse the relevant distance to be considered while observing the defuse surface of the rear projection screen As described in High Brightness precautions Hazard Distance HD page 6 it is mandatory to create a restricted zone within the beam areas closer than any NOHD In the enclo...

Page 11: ...1 Safety 1 6 HD in function of modifying optics DP2K 15CLP Hazard Distance Image 1 4 DP2K 20CLP Hazard Distance Image 1 5 R5906714 DP2K CLP SERIES 09 05 2016 9 ...

Reviews: