R5905754 /13
DPxK-32B
56
4.
Select the desired lamp (7) and click
OK
(8).
The article number and serial number of the selected lamp is added to the
Reset lamp parameters
window
(10). The lamp run time and number of strikes of this lamp are added in
Lamp parameter preview
(12).
5.
The lamp parameters can be edited by the user under personnel maintenance and responsibility. If you want
to change these parameters, check the check box in front of
Edit lamp parameters
(11).
The current parameter fields become active (12).
6.
Click in an input field and change to the desired value.
7.
Click
Reset lamp
(13).
4.9 Realignment of the lamp in its reflector (manual
Lamp House)
Each xenon lamp installation requires a realignment of the lamp in its reflector for optimal
performance of the xenon lamp in the DPxK-32B. Furthermore, it is recommended to realign the
lamp after the first run time of 100 and 200 hours. Especially the Z-axis of the lamp.
How to realign
1.
Remove the lamp cover to get access to the X-, Y- and Z-axis adjustment thumbscrews of the lamp.
2.
Some lamp houses may have lock nuts on the X and Y adjustment screws which are locked. Before starting
the adjustment, fully turn these lock nuts against the thumbscrew.
Image 4-34: Lock nuts
3.
Switch on the projector and start up the lamp.
4.
Go via the Communicator touch panel to the menu
“
Installation
”
>
“
Lamp
”
>
“
Light output
”
.
5.
Set the
“
Light output mode
”
in
normal mode
and the
“
Lamp Dimming
”
on maximum (
255
).
Note:
This window on the Communicator touch panel shows in the upper left corner the measured
value of the built-in light sensor of the projector.
Summary of Contents for DP K-32B Series
Page 1: ...ENABLING BRIGHT OUTCOMES User and Installation manual For DP2K 32B and DP4K 32B DPxK 32B ...
Page 8: ...R5905754 13 DPxK 32B 8 ...
Page 58: ...R5905754 13 DPxK 32B 58 Lamp Lamp House ...
Page 76: ...R5905754 13 DPxK 32B 76 Lenses lens holder ...
Page 94: ...R5905754 13 DPxK 32B 94 Input communication ...
Page 96: ...R5905754 13 DPxK 32B 96 Installing a HDD into the ICMP ICMP ...
Page 128: ...R5905754 13 DPxK 32B 128 Communicator Touch Panel ...
Page 154: ...R5905754 13 DPxK 32B 154 Maintenance ...
Page 162: ...R5905754 13 DPxK 32B 162 Convergence ...
Page 170: ...R5905754 13 DPxK 32B 170 Specifications ...
Page 188: ...Index R5905754 13 DPxK 32B 188 USB 3 0 101 User definition 10 Z Zoom 65 ...
Page 189: ...R5905754 13 DPxK 32B 189 ...
Page 190: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5905754 13 2018 11 12 ...