DCS-200 • User’s Guide
141
_K==oÉãçíÉ=`çåíêçä
Remote Commands
•
Parameters
:
-i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog); 1 - 9 for
query
-a (active): In pixels
•
Query Format
: IHATV -i (input) -?
•
Query Response
:
IHATV -i (input) -a (active) --min (active min) -- max (active max)
fe`olm=
•
Description
: Input Horizontal Crop
•
Command Format
: IHCROP -i (input) -w (width)
•
Parameters
:
-i (input): 1 - 9
-w (width): In pixels
•
Query Format
: IHCROP -i (input) -?
•
Query Response
: IHCROP -i (input) -w(width) --min (pos min) -- max (pos max)
fem^k=
•
Description
: Input Horizontal Pan
•
Command Format
: IHPAN -i (input) -p (pan)
•
Parameters
:
-i (input): 1 - 9
-p (pan): In pixels
•
Query Format
: IHPAN -i (input) -?
•
Query Response
: IHPAN -i (input) -p (pan) --min (active min) -- max (active
max)
femlp
•
Description
: Input Horizontal Position Adjust. This command is only adjustable
for analog input types. Other input types will provide query information only.
•
Command Format
: IHPOS -i (input) -p (position)
•
Parameters
:
-i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog); 1 - 9 for
query
-p (position): In pixels
•
Query Format
: IHPOS -i (input) -?
•
Query Response
:
IHPOS -i (input) -p (position) --min (pos min) -- max (pos max)