![background image](http://html1.mh-extra.com/html/barco/baron-908/baron-908_installation-manual_473866024.webp)
AC Power connections
5 - 2
5976418 BARON 908 04122001
Switching on the projector
Switching on
The projector is switched ON and OFF using the power (mains) switch.
Pressed : ON
Not pressed : OFF
POWER MAINS
COMM. PORT
REMOTEREMO
TE
IRIR
RS 232 OUTRS 232 OUT
RS 232 IN
R
G
B
Comp / H-Sync
V-Sync
R
G
B
Comp / H-Sync
S - VIDEO
75 Ohm
OFF - ON
75 Ohm
ON - OFF
75 Ohm
OFF - ON
75 Ohm
ON - OFF
red: standby
green: operation
red: standb
y
green: operation
S - VIDEO
VIDEO
VIDEO
V-Sync
RS 232 IN
PORT 3
COMM. POR
T
PORT 3
PORT 4 / 5
PORT 4 / 5
PORT 2
PORT 2
PORT 1
PROJECTOR MODE
PROJECT
OR MODE
PORT 1
ON
OFF
ON
POWER MAINS
800 periphals
800 periphals
This device complies with part 15 of the FCC rules.
Operation is subject to following two conditions (1).
This device may not cause harmful interference,
and (2) this device must accept any interference that
may cause undesired operation.
See installation instructions before connecting to the supply.
Voir la notice d' installation avont de raccorder au réseau.
See installation instructions bef
ore connecting to the supply .
Voir la notice d' installation a
vont de r
accorder au réseau.
This device complies with par
t 15 of the FCC rules
.
Operation is subject to f
ollowing tw
o conditions (1).
This device ma
y not cause harmful interf
erence,
and (2) this device m
ust accept any interf
erence that
may cause undesired oper
ation.
image 5.3
Power switch
OFF
Stand by indication lamp :
No light up : projector switched off
Green color : projector in Operational mode
Red color : projector is in Standby mode.
When switching on with the power switch, the projector can start now in :
1 Operational mode (picture displayed)
2 Stand by mode
The way of start up depends on the 'Power up' setting in the service mode.
Switching off
Use the same power switch to switch off the projector.
AC Power
The power voltage
The power input voltage of the 908 projector is autoranging between 100V (-10%) and 240V (+6%).
The power input voltage of the vacuum pump and controller unit is not autoranging and will depend on the ordered Baron:
230V Baron (R9040060)
120V Baron (R9040069)
Fuses
The following fuses are used inside the projector (these fuses are located behind the power switch 5.2):
2x T10A (Order number R314521)
1x F10A (Order number R314155)
The following fuse is used inside the control unit (image 5.1):
On a 230V Baron 908 (R9040060) = 230V Control Unit: 1x T1,25A (K314149)
On a 120V Baron 908 (R9040069) = 120V Control Unit: 1x T2,5A (V3141589)
For continued protection against fire hazard: replace with the same type of fuse and refer replacement to qualified service personnel.
Summary of Contents for BARON 908
Page 1: ...BARON 908 R9040060 R9040069 INSTALLATION MANUAL ...
Page 2: ......
Page 8: ...Table of contents 0 4 5976418 BARON 908 04122001 ...
Page 16: ...Packing and dimensions 2 4 5976418 BARON 908 04122001 ...
Page 26: ...ACPowerconnections 5 4 5976418 BARON 908 04122001 ...
Page 34: ...Sourceconnections 6 8 5976418 BARON 908 04122001 ...
Page 48: ...i 2 Index 5976418 BARON 908 04122001 ...
Page 49: ......
Page 50: ......