harmful interference to other devices, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving device.

Increase the separation distance between the equipment.

Connect the equipment to an outlet on a circuit different from that to which the other device(s) are
connected.

Consult the manufacturer or field service technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.

Because many medical offices are located in residential areas, this monitor, in addition to the medical
requirements, has also been tested and found to comply with the limits for FCC Class B computing devices in
a typically configured system. It is the system integrator or configurer

s responsibility to test and ensure that

the entire system complies with applicable EMC laws.

FCC responsible

: Barco Inc., 3059 Premiere Parkway Suite 400, 30097 Duluth GA, United States, Tel: +1

678 475 8000

Canadian notice

CAN ICES-3 (B)/NMB-3(B)

7.6 EMC notice

General information

This device is for use in professional healthcare facility environments only.

With the installation of the device, use only the delivered external cables and power supply or a spare part
provided by the legal manufacturer. Using another can result in a decrease of the immunity level of the device.

WARNING:

Use of this equipment adjacent to or stacked with other equipment should be avoided

because it could result in improper operation. If such use is necessary, this equipment and the other
equipment should be observed to verify that they are operating normally.

WARNING:

Use of accessories, transducers and cables other than those specified or provided by

the manufacturer of this equipment could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and result in improper operation.

WARNING:

Portable RF communications equipment (including peripherals such as antenna cables

and external antennas) should be used no closer than 30 cm (12 inches) to any part of the
AMM240ED, including cables specified by the manufacturer. Otherwise, degradation of the
performance of this equipment could result.

Electromagnetic emissions

The AMM240ED is intended for use in the electromagnetic environment specified below. The customer or the
user of the AMM240ED should assure that it is used in such an environment.

Emissions test

Compliance

Electromagnetic environment

Guidance

RF emissions
CISPR 11

Group 1

The AMM240ED uses RF energy
only for its internal function.
Therefore, its RF emissions are
very low and are not likely to cause
any interference in nearby
electronic equipment.

RF emissions
CISPR 11

Class B

The AMM240ED is suitable for use
in all establishments, including
domestic establishments and those
directly connected to the public low-
voltage power supply network that

Harmonic emissions
IEC 61000-3-2

Class D

Important information

Summary of Contents for AMM240ED

Page 1: ...ENABLING BRIGHT OUTCOMES User Guide AMM240ED...

Page 2: ...red office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco Inc 3059 Premiere Parkway Suite 400 Duluth GA 30097 USA www barco com en support www bar...

Page 3: ...us 12 4 Advanced operation 15 4 1 Chromatic 16 4 2 Visual 16 4 3 Setting 16 4 4 Advanced 17 4 5 Information 20 5 Cleaning your display 21 5 1 Cleaning instructions 22 6 Troubleshooting 23 6 1 Troubles...

Page 4: ...R5912858 05 AMM240ED 4 7 9 Legal disclaimer 37 7 10 Technical specifications 38 7 11 Connectors 40...

Page 5: ...05 AMM240ED Introduction Thank you for choosing this AMM240ED For future reference record the serial number of your display below The serial number is located on the back of the display Serial number...

Page 6: ...the box Overview Make sure the following items are present when you unpack the box AMM240ED LCD display the equipment that displays information graphic data image and video on the LED screen English u...

Page 7: ...or exit the OSD menu Left Decrease a setting or value Right Increase a setting or value or enter a submenu Up Move to the previous item Down Move to the next item Select Select an item Brightness Quic...

Page 8: ...2 3 4 5 6 7 8 9 10 Image 1 3 1 DC power 2 HD SD SDI1 IN 3 HD SD SDI1 OUT 4 HD15 RGBS IN 5 RS232C 6 USB 7 DVI I OUT 8 DVI I IN 9 HD SD SDI2 IN OPTIONAL 3 10 Y C IN AC Adaptor dimensions Image 1 4 Welc...

Page 9: ...r system also supports the DDC Display Data Channel protocol The DDC protocol is a communication protocol through which the monitor automatically informs the host system about its capabilities for exa...

Page 10: ...HD15 to the host system accordingly 2 Connect the DC power to the DC power connector on the monitor 3 Make sure that the AC power cord is the correct type required for the area 4 4 Connect one end of...

Page 11: ...11 R5912858 05 AMM240ED Daily operation 3...

Page 12: ...can be done by 1 If not already done so switch on the display 2 Press the menu button As a result the OSD main menu comes up Image 3 1 3 3 Navigating through the OSD menus How to navigate through the...

Page 13: ...hase Chroma Sharpness V Sharpness H Setting Adjust Scale Mode Color Space Freeze Frame Zoom Pan PIP POP PBP Advanced Adjust OSD Position Control Screen Control DPMS Auto Source Select Smart Select Res...

Page 14: ...R5912858 05 AMM240ED 14 Daily operation...

Page 15: ...15 R5912858 05 AMM240ED Advanced operation 4...

Page 16: ...ess H Set the Sharpness of Horizontal Image Range 0 20 6 4 3 Setting About setting The available functions are Scale Mode Change the Scale Mode Fill all One to One Vertical Fill Horizontal Fill Fill a...

Page 17: ...unctions are OSD Position Control Change the OSD Menu H and V Position Background OSD Time Out Language Screen Control Control and Adjust H and V position Freqency Phase Noise Reduction Motion Offset...

Page 18: ...itor goes into power off mode when the vertical and horizontal sync signals are off for about 10 seconds In this mode the screen goes off and the power LED blinks for 1 second On and 1 second Off The...

Page 19: ...1050 60Hz 64 742 59 946 119 125 1680 x 1050 60Hz 65 160 59 944 147 000 1600 x 1200 60Hz 74 077 59 981 130 375 1920 x 1080 60Hz 67 500 60 00 148 500 1920 x 1200 60Hz 74 099 59 999 154 125 Video Signals...

Page 20: ...o o o o o 1080 60i o o o o o 1080 50p o o 1080 60P o o 4 5 Information About information The available functions are Custom Entry Change the User or Monitor s Name Custom Entry Row 1 Custom Entry Row...

Page 21: ...21 R5912858 05 AMM240ED Cleaning your display 5...

Page 22: ...d using 70 isopropyl alcohol for the screen surface and warm water and a mild detergent for all other surfaces Other acceptable cleaning agents are 70 isopropyl alcohol Cidex 2 4 glutaraldehyde soluti...

Page 23: ...23 R5912858 05 AMM240ED Troubleshooting 6...

Page 24: ...eck if the AC power cord is properly connected to the AC Adaptor Power LED blinking Check if the video signal cable is properly connected at the back of the display Check if the power to the computer...

Page 25: ...25 R5912858 05 AMM240ED Important information 7...

Page 26: ...and inspect its routing so that it is not under the risk of being punched or cut Check the integrity of the protective earth connection Clean the area around the power plug Dust and liquids may result...

Page 27: ...d of time To disconnect the cord pull it out by the plug Never pull the cord itself 4 Test this equipment prior to a medical procedure This monitor was fully tested at the factory before shipment 5 Do...

Page 28: ...Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment To prevent possible harm to the environment or...

Page 29: ...homogeneous materials used for this part is above the limit requirement in GB T 26572 EIP EFUP Barco EFUP All Electronic Information Products EIP that are sold within Chinese Mainland must comply wit...

Page 30: ...s not intended to be used for direct diagnosis and therapeutic interventional radiology Intended users Surgical displays are intended to be used by trained medical practitioners Notice to the user and...

Page 31: ...esult in a decrease of the immunity level of the device WARNING Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation If suc...

Page 32: ...V air 8 kV contact 2 kV 4 kV 8 kV 15 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast tra...

Page 33: ...Pulse modulation 18 Hz 1 8 0 3 27 450 430 470 GMRS 460 FRS 460 FM 5 kHz deviation 1 kHz sine 2 0 3 28 710 704 787 LTE Band 13 17 Pulse modulation 217 Hz 0 2 0 3 9 745 780 810 800 960 GSM 800 900 TETRA...

Page 34: ...approved according to the VCCI regulations Indicates the device is approved according to the EAC regulations Caution Federal law United Stated of America restricts this device to sale by or on the or...

Page 35: ...onic Equipment directive Indicates Direct Current DC Indicates Alternating Current AC Stand by Protective earth ground Fragile handle with care Keep dry This way up Indicates the maximum number of box...

Page 36: ...ished units or equivalent product will be warranted for a period of twelve 12 months from the date of repair Limitation of Warranty This limited warranty does not cover any damage to this product or o...

Page 37: ...D TO THE PERIODS OF TIME SET FORTH ABOVE SOME STATES OR OTHER JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIO...

Page 38: ...roducts please inform us via contact details mentioned on https www barco com psirt To protect our customers Barco does not publicly disclose or confirm security vulnerabilities until Barco has conduc...

Page 39: ...ments 100 240 VAC 50 60 Hz Power consumption 40 W Dimensions packaged 665 x 240 x 640 H Weight Monitor 7 35 kg without cable cover without stand AC adaptor 410 g VESA mounting 75 x 100 mm Certificatio...

Page 40: ...ector Pin Description Pin Description Pin Description 1 T M D S Data2 9 T M D S Data1 17 T M D S Data0 2 T M D S Data2 10 T M D S Data1 18 T M D S Data0 3 T M D S Data2 Shield 11 T M D S Data1 Shield...

Page 41: ...deo Input HD SD SDI1 In Connector Pin Description Pin Description 1 SDI In 2 GND Video Input HD SD SDI1 Out Connector Pin Description Pin Description 1 SDI Out 2 GND Video Input HD 15 RGBS In Connecto...

Page 42: ...ion Pin Description 1 Vcc 5 V 2 NC 3 NC 4 GND Video Input HD SD SDI2 In optional Video Connector Pin Description Pin Description 1 SDI Input 2 GND Video Input Y C In Video Connector Pin Description Pi...

Page 43: ......

Page 44: ...www barco com R5912858 05 2021 05 19 Barco Inc 3059 Premiere Parkway Suite 400 Duluth GA 30097 USA Barco NV President Kennedypark 35 8500 Kortrijk Belgium...

Reviews: