Table 6: Minimum dimension and clearance to non-flammable ceiling
With false ceiling
Without false ceiling
h
Area of the convection air
outlet opening
Minimum 300 cm
2
Minimum 20 cm open space
between ceiling and chim-
ney enclosure
H
Height of the false ceiling
Minimum 50 mm (= thick-
ness false ceiling)
Not applicable (the top side
of the chimney enclosure is
open with a clearance of
minimum 20 cm to the ceil-
ing.
A
Distance between convec-
tion air outlet opening and
ceiling
Minimum 50 cm
Minimum 50 cm open space
between ceiling and chim-
ney enclosure
5.7
Clearances in front of the appliance
Do not put flammable items within minimum 180 cm radius from the appliance.
1
Non-flammable floor plate
2
Appliance
Clearances
20
Unilux-7 75