3
UNILUX-6 67
Instructions for use
1.
Unique identification code of the product-type
2.
Intended use or uses of the construction product, in
accordance with the applicable harmonised technical
specification, as foreseen by the manufacturer
3.
Name, registered trade name or registered trade mark
and contact address of the manufacturer as required
pursuant to Article 11(5)
4.
Where applicable, name and contact address of the
authorised representative whose mandate covers the
tasks specified in Article 12(2)
5.
System or systems of assessment and verification of
constancy of performance of the construction product
as set out in Annex V
6.
In case of the declaration of performance concerning a
construction product covered by a harmonised
standard
7.
Declared performance
Fire safety
Distance to combustible materials
Minimum distances, in mm
Insulation thickness rear =
100
Insulation thickness sides =
100
Insulation thickness ceiling =
100
Front =
800
Insulation thickness floor =
100
NPD
Thermal output
Energy efficiency
8.
Signed for and on behalf of the manufacturer by:
Danny Baijens, CEO
(Name and function)
Bladel; September 18, 2018
………………………………………………………………………..
(place and date of issue)
(Signature)
The performance of the product identified in point 1 is in conformity with the declared performance in point 7.
This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 3.
Water heating output
- kW
Pass
Nominal heat output
10 kW
Room heating output
10 kW
Electrical safety
Pass
Cleanability
Pass
Maximum operating pressure
Not applicable
Flue gas temperature at nominal heat output
T = 324 °C
75 %
NPD
Pass
Risk of burning fuel falling out
Pass
Declaration of Performance
According to regulation (EU) 305/2011
No. 1.815.003-2 - CPR-2013/07/01
Unilux-6 67
Room heater without hot water supply
Barbas Bellfires BV; Hallenstraat 17; 5531 AB Bladel; The Netherlands
Not applicable
System 3
The notified laboratory SGS Nederland BV, No. 0608 performed the
determination of the product type on the basis of type testing under system 3
and issued test report EZKA/2015-02/00001-16
Harmonized technical specification
EN13229:2001/A2:2004/AC:2007
Essential characteristics
Performance
CO = 0.07 vol%
Emission of combustion products
Mechanical resistance (to carry a chimney/flue)
Surface temperature
Release of dangerous substances
Pass