29
UNILUX-6 40
Instructions for use
9
TECHNICAL DATA
Combustion:
Measured in compliance with
EN 13229 : 2001 and EN 13229 - A2 : 2004
Fuel
Wood
Nominal output
5 kW
Effi ciency
76%
Emissions (dry, at 13% O
2
, 273 K, 1013 hPa):
Carbon monoxide (CO)
0.09%; 1043 mg/m
3
Dust
40 mg/Nm
3
Total hydrocarbons (C
x
H
y
)
83 mg/m
3
Nitrogen oxides (NO
x
)
128 mg/m
3
Flue gas mass fl ow
5.8 g/s
Flue temperature
293°C
Chimney draught
0.12 mbar
Flue gas connection
Ø122 mm (Ø128 mm ext.)
Weight
69 kg
Inside:
Interior side panels
Heat-resistant panels 1400 kg/m
3
, 1300°C
Interior bottom
Steel (heat-resistant and rust-proof)
Inner lining
Steel (heat-resistant and rust-proof)
Bottom baffl e plate
Heat-resistant panel 2000 kg/m
3
, 1300°C
Top baffl e plate
Stainless steel
Outside:
Construction
Sheet-steel casing.
Doors
Flat door opening to left.
Shutter with fi xed handle.
Operation:
• Handle for opening the door.
• Combustion air supply slider
Single combined slide for controlling the
primary, secondary and tertiary air supply.
Ash collection:
Ashtray with grate.
Combustion air supply:
At least 50 cm
2
opening in the room where the
fi re is located or a outside air supply opening of
Ø80 mm in wall/fl oor.
Clean Air Act exemption:
The appliance has been factory-fi tted with an air
slide designed for use also in Smoke Control Areas.