88
Technical data
8.1
Technical data
Table 8: Technical data Falcon 73/63
Name
Barbas
Model
Falcon 73/63
Tested in accordance with
EN 13229:2001-A2:2004
EN16510-1 annex D, E, F
Energy efficiency index
99.9
Energy efficiency class
A
Fuel
Wood logs, Wood briquettes
Nominal fuel load
2.8 kg
Nominal heat output (net)
12.3 kW
Minimum heat output (net)
8 kW
Useful efficiency at nominal heat output
75.2 %
Useful efficiency at minimum heat output (indi-
cative)
79 %
Indirect heating function
No
Leak rate at 10 Pa
1.3 m
3
/h (at 273 K, 1013 hPa)
Emissions (at 13 % O
2
, 273 K, 1013 hPa)
• carbon monoxide (CO)
0.07 vol% (932 mg/Nm
3
)
• particles (PM)
24 mg/Nm
3
• organic gaseous compounds (OGC)
50 mg/Nm
3
• nitrogen oxides (NO
x
)
85 mg/Nm
3
Flue gas mass flow
13.1 g/s
Flue gas temperature
350 °C
Chimney draught
12 Pa (0,12 mbar)
Flue gas connection
Ø 207 mm, suitable for a pipe with an outer di-
ameter of 200 mm
Weight
• Basic appliance
• Áppliance with adjustable height frames and
convection ventilator
• 218 kg
• 236 kg
Minimum insulation thickness to combustible
walls
• side wall
• back wall
• floor
• ceiling
• 100 mm
• 100 mm
• 100 mm
• 40 mm
Used materials
• Combustion chamber side panels
Cast iron
Technical data
Falcon 73/63
29
Summary of Contents for Falcon 73
Page 28: ...Annual maintenance 2 28 Falcon 73 63...
Page 31: ...9 9 Dimensions 9 1 Frameless appliance Dimensions Falcon 73 63 31...
Page 33: ...9 9 3 Appliance with 3 sided classic frame Dimensions Falcon 73 63 33...
Page 34: ...9 9 4 Appliance with 4 sided classic frame Dimensions 34 Falcon 73 63...
Page 37: ...Warranty Terms Falcon 73 63 3 37...
Page 38: ...Warranty Terms 3 38 Falcon 73 63...