Control lever in the far right position:
primary air inlet maximum open
secondary air inlet maximum open
airwash inlet maximum open
Control lever in the center position:
primary air inlet is closed
secondary air inlet maximum open
airwash inlet maximum open
Control lever in the far left position:
primary air inlet is closed
secondary air inlet is closed
airwash inlet is closed
6.3.4
General firing tips
• The appliance works best when it has heated up as described in section
.
Insufficient heating up leads to a low chimney draught, black deposits on the glass
and incomplete combustion. Good combustion is recognized by bright orange flames,
invisible smoke and no soot deposits on the glass. Use the control lever to get good
for advice on the required fuel quality.
• Make sure the door of the appliance is closed when in use. Only open the door for
ignition and to refuel.