Gas Conversion – PART A - MANUAL SYSTEMS –
NOTE: CONVERSION SHOULD BE COMPLETED BEFORE BURNER IS INSTALLED.
Caution- the gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the
conversion.
TO CONVERT MAP SYSTEMS TO MAN:
1. Remove [2] screws from Orifice Retainer Bracket.
2. Remove Burner Orifice from Air Shutter. Using a 1/2” wrench,
disconnect Burner Orifice from brass fitting and replace with
supplied NG Burner Orifice.
3. Set Air Shutter Adjustment to
1/16”
.
4. Re-insert new Burner Orifice into Air Shutter.
5. Re-attach Orifice Retainer Bracket to Burner Tray.
6. Disconnect LP Hose and Regulator from Valve Assembly.
TO CONVERT MAN SYSTEMS TO MAP:
1. Remove [2] screws from Orifice Retainer Bracket.
2. Remove Burner Orifice from Air Shutter. Using a 1/2” wrench,
disconnect Burner Orifice from brass fitting and replace with
supplied LP Burner Orifice.
3. Set Air Shutter Adjustment
Fully Open
.
4. Re-insert new Burner Orifice into Air Shutter.
5. Re-attach Orifice Retainer Bracket to Burner Tray.
6. Connect LP Hose and Regulator to Valve Assembly.
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer’s instructions and all applicable codes and requirements of the Authority
Having jurisdiction. If the information on in these instructions is not followed exactly, a fire,
explosion or production of carbon monoxide may result causing property damage,
personal injury or loss of life.
The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is
checked as specified in the manufacturer’s instructions supplied with the kit.
Air Shutter Adjustment:
1/16” for Natural Gas
Fully Open for Propane
Burner Orifice
See Chart for Size
Orifice Retainer Bracket
Burner Tray
TANK RETAINER
Included with all MAP Burners and LP
Conversion Kits
NOT USED ON FIRE TABLES.
10ft LP Hose & Regulator
Included in 24OB-CKLP10
5ft LP Hose & Regulator
Included in MAP Systems &
24OB-CKLP5
PN: 27FP-900FF
PN: 24OFS-P120
43