background image

OUTDOOR LINEAR FIRE PIT MANUAL 

OUTDOOR BURNERS:

 OB24MAN, OB24MAP, OB24MVN, OB24MVP,  

OB36MAN, OB36MAP, OB36MVN, OB36MVP,  

OB48MAN, OB48MAP, OB48MVN, OB48MVP,  

OB72MVN, OB72MVP, OB96MVN, OB96MVP 

-CERTIFIED FOR USA & CANADA- ANSI Z21.97-2014 • CSA 2.41-2014 OUTDOOR DECORATIVE GAS APPLIANCES 

 NOTE: LP MANUAL (MAP) VALVE SYSTEMS ARE SHIPPED WITH AN ACCOMPANYING ORIFICE FOR NG CONVERSION.  

ALL MILLIVOLT VALVE SYSTEMS ARE SHIPPED AS NG SYSTEMS (MVN) AND REQUIRE A CONVERSION KIT FOR LP CONVERSION. 

OUTDOOR FIRE STANDS

 (c/w Burner)

:

 OFS24MAN, OFS24MAP, OFS36MAN, OFS36MAP, OFS48MAN, OFS48MAP  

OUTDOOR FIRE TABLES 

(Burner Required)

:

 OLTN24, OLTW24, OLTN36, OLTW36, OLTN48, OLTW48 

 

OUTDOOR FIREPLACES 

(Burner Required)

:

 

OFP4336S1, OFP4336S2, OFP5548S1, OFP5548S2, OFP7972S1, OFP7972S2 

 

 

 

⚠ 

DANGER

 

If you smell gas: 
1. Shut off gas to the 

appliance. 

2. Extinguish any open flame. 

3. If odor continues, keep 

away from the appliance 

and immediately call your 

gas supplier or fire 

department.

 

⚠ 

WARNING

 

Do not store or use gasoline 

or other flammable vapors and 

liquids in the vicinity of this or 

any other appliance. 
An LP-cylinder not connected 

for use shall not be stored in 

the vicinity of this or any other 

appliance.

 

⚠ 

WARNING

 

For Outdoor Use Only. 

⚠ 

WARNING

 

Improper installation, 

adjustment, alteration, service 

or maintenance can cause 

injury or property damage. 

Read the installation, 

operating and maintenance 

instructions thoroughly before 

installing or servicing this 

equipment. 

 

 

DANGER

 

CARBON MONOXIDE HAZARD 
This appliance can produce carbon 

monoxide which has no odor. 

 

Using it in an enclosed space can 

kill you. 

 

Never use this appliance in an 

enclosed space such as a camper, 

tent, car or home. 

 

 

 

Kingsman Fireplaces   2340 Logan Ave., Winnipeg, Mb Canada Ph: 204-632-1962           Printed in Canada P/N 24LFP-MAN May 28, 2018 

INSTALLER:

 Leave this manual with the appliance. 

CONSUMER:

 Retain this manual for future reference. 

This appliance is designed as an “attended appliance”. Adults 

must be present when the unit is operating. DO NOT leave this 

unit burning when unattended. If this product is left burning 

unattended it may cause damage or serious injury. 

OLTN / OLTW

 

OUTDOOR FIRE TABLE 

OFP S1 / S2

 

OUTDOOR FIREPLACE 

OB

 

OUTDOOR BURNER 

OFS 

OUTDOOR FIRE STAND 

 

Summary of Contents for OB24MAP

Page 1: ...and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING For Outdoor Use Only WARNING...

Page 2: ...ive abrasion or wear or the hose is damaged it must be replaced prior to the appliance being put into operation Locate the hose out of pathways where people may trip over it or in areas where the hose...

Page 3: ...21 Outdoor Fire Tables 20lb Cylinder Installation 22 OUTDOOR FIREPLACES Outdoor Fireplaces OFP OFP4336S1 OFP4336S2 Dimensions 23 Outdoor Fireplaces OFP OFP5548S1 OFP5548S2 Dimensions 24 Outdoor Firepl...

Page 4: ...ds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace Note to the Installer Be sure appliance is working properly and its operation including...

Page 5: ...that includes an overhead cover and three side walls as long as 30 percent or more of the horizontal periphery of the enclosure is permanently open All models can be installed safely in a screened po...

Page 6: ...t Canada Not to be installed above a gas meter regulator assembly within 3ft horizontally from the center line of the regulator Not allowed Vinyl NOTE Diagrams Illustrations not to scale A fireplace s...

Page 7: ...Fire Stand is available with a Manual Valve only OB24 OFS24 OB36 OFS36 OB48 OFS48 Outdoor Fire Tables OLTN OLTW Approved Accessory Burner is ordered separately LISTED BURNER OFT Outdoor Fire Table MA...

Page 8: ...wide x 38 long x 2 tall OFS36MAN OLTN36 OLTW36 N A OB36MVN SIT Millivolt NG Burner For LP order 36OBCKLP 7 1 2 wide x 38 long x 2 tall N A OLTN36 OLTW36 OFP4336S1 OFP4336S2 OB48MAP Dante Manual LP Bur...

Page 9: ...Burners with Label Dimensions OB24 OB36 OB48 OB72 OB96 Outdoor Burners OB24 BURNER OB36 BURNER OB48 BURNER OB72 BURNER OB96 BURNER END VIEW ALL BURNERS 2 1 16 2 5 16 38 2 5 16 2 1 16 50 2 5 16 2 5 16...

Page 10: ...t with 2 DT Screws Parts List OB24 OB36 OB48 MAP MAN 1 Burner c w 1 Pilot Shield 2 Ends 3 Filler Strips 1 Manual Valve c w Regulator 5ft Hose for LP Systems 1 Push Button Igniter c w wire and Sparker...

Page 11: ...Sparker 1 On Off Rocker Switch installed on valve 1 Pilot Opening Cover 1 Hardware Bag 12 1 2 DT Screws 8 6 Black Screws 2 10 24 x 1 2 Bolts c w Star Nuts 6 Filler Strips 1 Cover Clip 24OB 23 9 16 36...

Page 12: ...penings for Stock Burners OB24 5 3 4 x 24 1 2 OB36 5 3 4 x 36 1 2 OB48 5 3 4 x 48 1 2 OB72 5 3 4 x 72 1 2 OB96 5 3 4 x 96 1 2 Burners may be connected together in any combination When connecting burne...

Page 13: ...Valve Mount can be used to mount either the millivolt or manual valve in a custom enclosure Parts Included Qty 6 DT Screws Universal Valve Mount Manual Valve Systems Millivolt Valve Systems Universal...

Page 14: ...ain access to the cylinder valves is acceptable provided it is non locking and can be opened without the use of tools Designs using a cover to gain access to the cylinder and cylinder valve shall be p...

Page 15: ...be placed into a non combustible custom enclosure provided air openings are provided as specified in Locating Your Appliance Minimum Clearances to Combustibles Burners Fire Stands Tables section and V...

Page 16: ...ss Orifice for NG Gas Conversion LP Systems 1 Tank Retainer 2ea Wood Screws LP Systems OFS24 Shown Ready for Media Placement See Media Section of Manual for Options END VIEW Outdoor Fire Stand FILLER...

Page 17: ...Minimum Clearances to Combustibles Burners Fire Stands Tables section for safe placement of this appliance OLTN24 BURNER OPTIONS OB24MAP c w 40 Orifice for NG OB24MAN Order 24OB CKLP5 for LP OB24MVN...

Page 18: ...nimum Clearances to Combustibles Burners Fire Stands Tables section for safe placement of this appliance OLTN36 BURNER OPTIONS OB36MAP c w 31 Orifice for NG OB36MAN Order 36 48OB CKLP5 for LP OB36MVN...

Page 19: ...nimum Clearances to Combustibles Burners Fire Stands Tables section for safe placement of this appliance OLTN48 BURNER OPTIONS OB48MAP c w 30 Orifice for NG OB48MAN Order 36 48OB CKLP5 for LP OB48MVN...

Page 20: ...or 6 bolts NOTE Tank Brace Tank Shield must be on the same side as the Tank Mount Hole Step Four Install Tank Brace with Washer and Thumbscrew Carefully lift and place Fire Table upright Install Door...

Page 21: ...valve to Mount Plate on table MANUAL VALVE SETUP OPTIONAL ELECTRONIC SPARK ASSIST OB Burner and Valve Assembly Valve Mount Bracket Valve Mount Plate DT Screw DT Screw DT Screw DT Screw 6 Black Screws...

Page 22: ...ly supplied with LP models PN 27FP 900FF must be used Replacement pressure regulators and hose assemblies must be those specified in this manual Always check for gas leaks with a soap and water soluti...

Page 23: ...aces OFP4336S1 and OFP4336S2 Dimensions Outdoor Fire Place OFP4336S1 Millivolt Natural Gas Convert to LP with Conversion Kit 36OB CKLP OFP4336S2 Millivolt Natural Gas Convert to LP with Conversion Kit...

Page 24: ...aces OFP5548S1 and OFP5548S2 Dimensions Outdoor Fire Place OFP5548S1 Millivolt Natural Gas Convert to LP with Conversion Kit 48OB CKLP OFP5548S2 Millivolt Natural Gas Convert to LP with Conversion Kit...

Page 25: ...aces OFP7972S1 and OFP7972S2 Dimensions Outdoor Fire Place OFP7972S1 Millivolt Natural Gas Convert to LP with Conversion Kit 72OB CKLP OFP7972S2 Millivolt Natural Gas Convert to LP with Conversion Kit...

Page 26: ...ELY HEAVY Ensure that fireplace is properly supported when handling Tab cutouts on the faces of the appliance can be used to assist with handling and locating fireplace Cutouts are for Hand use or 2 x...

Page 27: ...ace can be used to assist installation NOTE Support Guide is NOT load bearing Bottom of fireplace MUST be supported Set Support Guides at desired height and attach with DT Screws Support Guide Support...

Page 28: ...ES OFP4336 OFP5548 OFP7972 S1 S2 section for Non combustible areas 1 2 Plywood Exterior Facing Fold Nailing Tabs back onto framing Fold Nailing Tabs back onto framing SIDE OF UNIT RIGHT SIDE OF UNIT B...

Page 29: ...s In Front of Unit 36 Face or Facing of Fireplace Top Sides and Back of Appliance 0 Standoffs ALCOVE Alcove Depth All Units 36 Face or Facing of Fireplace Alcove Width OFP4336S1 S2 60 Fireplace Openin...

Page 30: ...5SS OFP79SS STEP 1 Place bottom of Side Filler into gap at corner of opening STEP 2 Push Side Filler into place Repeat procedure for other side STEP 3 Hook Surround Frame onto Lower Edge of fireplace...

Page 31: ...R CAN BE USED WITH OR WITHOUT SURROUND STEP 1 Insert left side of Weather Cover into fireplace opening STEP 2 Insert right side of Weather Cover into fireplace opening Slide to the right until gap is...

Page 32: ...nts such as the warm highly humid atmosphere around pools and hot tubs These stains could be perceived as rust but can be easily removed or prevented To provide stain prevention and removal wash all s...

Page 33: ...o remove burner 1 Disconnect gas supply Caution only a qualified person should do this 2 Remove Access Cover 3 Remove Screws in Burner Tray and Valve Bracket TO INSTALL BURNER REVERSE ABOVE STEPS ACCE...

Page 34: ...lbs MQG5C Glass Media 1 2 Bronze 5 lbs MQG5W Glass Media 1 2 White 5lbs Use of any other glass can alter the performance of the unit and is not covered under warranty Discoloration of glass media may...

Page 35: ...rative Stones 80 Piece Set MQSTONE10 Decorative Stones 10 Piece Set Place Rocks and Stones randomly Do not cover Pilot Not all Rocks or Stones will be used on all models RBCB1 Canonballs Assorted Size...

Page 36: ...pped screws 2 Glass End Panels 2 Glass Side Panels O24WG 24 Wind Guard O36WG 36 Wind Guard O48WG 48 Wind Guard O72WG 72 Wind Guard O96WG 96 Wind Guard Wind can greatly affect flame performance If used...

Page 37: ...rner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN This appliance is not intended for use in temperatures below freezi...

Page 38: ...st have threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed area Storage of this appliance indoors is permissible only if it has been disconnected...

Page 39: ...gas control valve 4 Place a burning match on top of burner in the middle where ports are present DO NOT HOLD THE MATCH IN HAND For Natural Gas unit turn on the on off valve slowly at the unit For LP u...

Page 40: ...rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter butt...

Page 41: ...ote The gas line connection may be made of 1 2 rigid pipe 1 2 copper pipe or an approved flex connector Since some municipalities have additional local codes it is always best to consult your local au...

Page 42: ...s for input rates Refer to Lighting Instructions for normal sequence of the ignition system TANK RETAINER Included with all MAP Burners and LP Conversion Kits 1 Connect foot ring of LP Tank to Tank Re...

Page 43: ...fice into Air Shutter 5 Re attach Orifice Retainer Bracket to Burner Tray 6 Connect LP Hose and Regulator to Valve Assembly WARNING This conversion kit shall be installed by a qualified service agency...

Page 44: ...n Kit also see Parts B C of Conversion Kit Instructions WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicab...

Page 45: ...new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Page 46: ...Gas Conversion for Modulator PART C 46...

Page 47: ...attery powered module is available to assist in lighting the pilot burner See below for installation Battery Igniter OLTN OLTW Top View OFP Top View OLTN OLTW Ignition Switch Ignition Switch Battery I...

Page 48: ...e Check wall switch and wires for proper connections Jumper wire across terminals at wall switch If burner comes on replace defective wall switch If okay jumper wire across wall switch wires at valve...

Page 49: ...P16FF 3 8 Stainless Steel Flex Connector 16 Long 3 24OB 102 Orifice Retainer Bracket 4 27FP P904FF 3 8 Tube OD x 1 8 MPT 5 1000 225 Brass Orifice NG or LP Specify size Refer to Chart in Manual 6 26ID...

Page 50: ...tainer Bracket 10 Hose Regulator GLASS MEDIA 5 lbs per Foot of Burner i e 24 burner 10lbs MQG5ZG Glass Media ZIRCON Glacier Ice 5 lbs MQG5A Glass Media 1 2 Cobalt Blue 5 lbs MQG5B Glass Media 1 2 Blac...

Page 51: ...r Brackets 8pcs and Rubber Feet 4pcs OB72WG Wind Guard for 72 Burners c w Tempered Glass 4pcs Corner Brackets 8pcs and Rubber Feet 4pcs OB96WG Wind Guard for 96 Burners c w Tempered Glass 4pcs Corner...

Page 52: ...te will be based upon the date of manufacture plus thirty 30 days Any labor material freight and or handling charges associated with any repair or replacement pursuant to this limited warranty will be...