background image

9

CONNECTION TO THE POWER MAINS 

  

Before making the connection, make certain 

that the voltage and frequency indicated on the data 
plate match those of the power supply system.

The appliance is supplied with a power cord and 3 pin plug. 
Plug  the  3-pin  plug  into  a  properly  earthed,  10A  general 
purpose power outlet (fig. 4a). If the appliance is not supplied 
with a plug or if connecting the cable directly to the mains 
(fig. 4b), this must only be done by an authorized person in 
accordance with current regulations in the country where the 
appliance is installed. The installation must include a means 
for disconnection from the supply having an air gap contact 
separation  in  all  active  conductors  that  allows  complete 
disconnection  in  category  III  overvoltage  conditions.  The 
isolating switch should be sized according to the load on the 
data label and should comply with current regulations. If the 
supply cord is damaged , it must be replaced by the manu-
facturer or its service agent or an authorised person in order 
to avoid hazard. 

The isolating switch must be located in 

a position which is accessible even after the appliance 
is installed. If the appliance is installed together with 
a oven, the connection of the two appliances must be 
independent for electrical safety reasons.

 The power cord must 

NOT

:

-   be crushed or rolled up;
-   come into contact with any type of liquid, sharp or hot 

objects or corrosive substances; 

-   reach, at any point, a temperature which is 50°C higher 

than the room temperature;

-   be replaced with a different type of cable 

(see “Techni-

cal data” on page 4)

 or with a cable which is not up to 

standard;

-   be lengthened with extensions.

COLLEGAMENTO ELETTRICO 

   

Prima  dell’allacciamento  accertarsi  che  la 

tensione e la frequenza riportate sulla targhetta ca-
ratteristiche corrispondano a quelle dell’impianto di 
alimentazione.

Il forno è dotato di un cavo di alimentazione con una spina 
a 3 poli. Collegare il connettore a 3 poli ad una
presa elettrica con messa a terra che sopporti un’intensità 
di corrente pari a 10A (fig. 4a). Se l’apparecchio non viene 
fornito con una spina o se il cavo viene connesso diretta-
mente alla rete (fig. 4b): l’operazione deve essere fatta da una 
persona autorizzata in conformità alla normativa vigente 
nel  Paese  di  installazione.  L’impianto  deve  prevedere  un 
dispositivo  che  assicuri  la  disconnessione  dalla  rete  con 
una distanza tra i contatti che consenta la disconnessione 
completa nelle condizioni della categoria di sovratensione 
III. L’interruttore deve essere dimensionato in funzione del 
carico sulla targhetta matricola e deve essere conforme alle 
normative vigenti. Se il cavo di alimentazione è danneggiato 
esso deve essere sostituito dal Costruttore o dal suo servizio 
di Assistenza Tecnica o comunque da una persona qualifica-
ta similare, in modo da prevenire ogni rischio.

Sia la presa di corrente che l’interruttore onnipolare devo-
no essere a norma e collocati in posizione accessibile anche 
con l’apparecchiatura incassata. Se l’apparecchiatura viene 
inserita in abbinamento a un forno, l’allacciamento delle 
due apparecchiature deve essere indipendente per motivi 
di sicurezza elettrica.

 Il cavo di alimentazione 

NON

 deve:

-   essere schiacciato o arrotolato su se stesso;
-   entrare  in  contatto  con  liquidi  di  qualsiasi  tipo, 

oggetti taglienti o caldi e sostanze corrosive; 

-   raggiungere in nessun punto una temperatura che 

superi di 50°C la temperatura ambiente;

-   essere sostituito con uno di tipo diverso 

(vedi “Dati 

tecnici” pag. 4)

  o non a norma;

-   essere allungato con prolunghe.

9

H05V2V2-F

3x1mm

2

90 cm

220V-240V  50HZ

 0,000 Kw 

Questo apparecchio deve essere installato conformemente alle norme in 

vigore e utilizzato solamente in locale ben areato. Consultare il libretto 

istruzioni prima di installare e usare l'aparecchio.

N°: XXXXXXXXX

CATEGORIA      II 2H3+            IT

F.lli BARAZZA s.r.l.

MADE IN ITALY

XXXXX       
XXXXX       
XXXXX       

MOD
ART

istruzioni prima di installare e usare l aparecchio.

B

A

10A

4

Summary of Contents for 1PMD64

Page 1: ...1PMD64 1PMD64B 1PMD95 1PMD95B 1PMD95W 1PMD104 1PMD104B taste of design Piani cottura Mood Mood Hobs Manuale d installazione e uso Installation and use manual...

Page 2: ...i apportare ai propri prodotti e a questo manuale le modifiche che riterr opportune senza obbligo di preavviso I disegni gli schemi di installazione e le tabelle contenuti all in terno del manuale son...

Page 3: ...enze di sicurezza 26 Manutenzione ordinaria 27 Pulizia 27 Periodi di inattivit 29 Smaltimento a fine vita 29 Assistenza post vendita 29 DESCRIPTION PAGE TECHNICAL DATA 4 INSTALLATION 6 Safety warnings...

Page 4: ...type H05V2V2 F 3x1 mm2 H05V2V2 F 3x1 mm2 Lunghezza cavo Cable length cm 90 90 510 510 400 mm 650 860 1100 65 65 1PMD64 1PMD64B 90 90 110 110 1PMD95 1PMD95B 1PMD95W mm mm 1PMD104 1PMD104B 40 51 4 R 6 R...

Page 5: ...kPa 1 00 kPa 4 0 MJ h 4 0 MJ h 0 56 0 92 0 325 Fully In 0 325 1 4 turn Semirapido Semi rapid Universal LPG Natural gas 2 75 kPa 1 00 kPa 7 2 MJ h 7 0 MJ h 0 75 1 20 0 425 Fully In 0 425 1 4 turn Rapid...

Page 6: ...tentamentequestolibrettodiistruzioni prima dell installazione e o dell uso dell appa recchiatura e conservarlo in un luogo accessibile a tutti gli utilizzatori per consultazioni future in caso di cess...

Page 7: ...ackaging film instructions bag expanded polystyrene impact protections CONTROLLO E MOVIMENTAZIONE Dopoaverdisimballatol apparecchiaturarimuovendo tutti i materiali di imballo e le pellicole a protezio...

Page 8: ...essuna superficie entro 45 cm sopra il bruciatore NOTA Qualora venga installata una cappa sopra il piano cottura consultare le istruzioni di montaggio della cappa nelle quali riportata la distanza cor...

Page 9: ...ntazione con una spina a 3 poli Collegare il connettore a 3 poli ad una presa elettrica con messa a terra che sopporti un intensit di corrente pari a 10A fig 4a Se l apparecchio non viene fornito con...

Page 10: ...thepowercordcanbereplaced withanidenticaltype see Technicaldata onpage 4 in compliance with current regulations in the country where the appliance is installed If the appliance is already connected di...

Page 11: ...e il tubo non sia a contatto con lo scarico fumi di un forno Il tubo non deve essere sottoposto ad abrasione annodamento odeformazionepermanenteedoveessereispe zionabile in tutta la sua lunghezza GAS...

Page 12: ...entazione di 2 75kPa dovrebbe essere parte della fornitura del serbatoio del gas Ad installazione ultimata controllare la perfetta tenuta di tutti i raccordi utilizzando una soluzione di acqua e sapon...

Page 13: ...at the pressure regu lator is correctly calibrated Check the gas supply pipe check that the pipe is not obstructed folded crushed too long unsuitable etc Ad installazione ultimata provate ad accendere...

Page 14: ...imo a quella di minimo non si abbiano spegnimentideibruciatori Eventualmenteaumen tare la portata dei minimi stessi agendo sulla vite di regolazione 1 2 7 REGULATING THE MINIMUM Adjust the low flame o...

Page 15: ...Pa dovrebbe essere parte della fornitura del serbatoio del gas Sostituire l etichetta di identificazione di Gas Naturale con quella del gas GPL Universale 2 4 3 1 8 GAS CONVERSION Removetheracks thefl...

Page 16: ...ata ventilazione nella parte inferiore del piano di cottura mm mm Incasso Built in 65 65 90 90 4 mm 590 490 830 480 mm 1070 370 110 110 9A BUILT IN UNIT INSTALLATION Make certain that the cabinet in w...

Page 17: ...etro ceramica installare le staffe in dotazione fig 10B per prevenire la caduta del piano in caso di rottura del vetro EMBEDDED SURFACES Place a protective sponge sealant under the hob figure 10A part...

Page 18: ...nelle vicinanze dell apparecchiatura potrebbe essere molto calda prestare cautela nel posizionare in questo spazio prese di cor rente altri elettrodomestici cavi elettrici tu bazioni e qualsiasi mate...

Page 19: ...ttore non si ritiene responsabile e non riconosce il diritto di Garanzia se questa norma non viene applicata FOR COOKING Burn hazard During operation and for a few minutes after use some parts of the...

Page 20: ...n areato Consultare il libretto istruzioni prima di installare e usare l aparecchio N XXXXXXXXX CATEGORIA II 2H3 IT F lli BARAZZA s r l MADE IN ITALY Qn g h XXXXX XXXXX XXXXX MOD ART N istruzioni prim...

Page 21: ...serigrafia ripor tata vicino alle stesse che identifica in modo chiaro ed inequivocabile il bruciatore al quale collegata la manopola fig 13A In order to determine which knob controls which cook ingz...

Page 22: ...uto allacombustionedeigrassiutilizzatiperlalavorazione in fabbrica della stessa arieggiare i locali USEFUL INFORMATION Before using the appliance for the first time carefully clean the appliance inclu...

Page 23: ...1 e 2 tenendo premuta pi a lungo la manopola dopo l accensione del bruciatore 23 1 9 MAX MIN 5 2 1 3 7 8 2 14 USING THE BURNERS Before using the appliance check that the flame distributors 2 the burne...

Page 24: ...riglia fig 16 Non consentitoutilizzare l apparecchiaturasenzalagrigliaocondiffusori dicaloreoriduttoridiversidaquelliacquistabili dal Rivenditore fig 17 24 OK 15 Flame control 3 Check that the flame i...

Page 25: ...valvole del gas sono difficili da girare Nel caso in cui l apparecchio non funzioni correttamen te contattare il Servizio Assistenza autorizzato di zona Monitortheapplianceduringtheentiretime it is i...

Page 26: ...a lungo sull apparecchiatura potrebbero intac care le superfici creando antiestetici aloni che non pregiudicano comunque la funzionalit dell apparec chiatura SAFETY WARNINGS Always disconnect the app...

Page 27: ...ntate tale operazione riservata all installatore per la regolazione del minimo per la loro pulizia utilizzare un panno MAINTENANCE SCHEDULE No regular maintenance is required for the hotplates except...

Page 28: ...tarsi che non vi siano impurit all interno delle coppe portaugello 6 in tal caso rimuoverle aspiran dole senza utilizzare detergenti liquidi o similari 28 2 3 6 18 to clean them use a soft cloth dampe...

Page 29: ...tendere che siano utilizzati unicamente ricambi originali l utilizzo di componentistica diversa da quella fornita dal Costruttore fa decadere la Garanzia e pu arrecare danni alle persone e all apparec...

Page 30: ...Note...

Page 31: ......

Page 32: ...Progetto grafico Artlinea it cod PMOO3 rev 00 01 2018 Abey Australia 57 81 Abey Road PO Box 985 Melton Victoria 3337 Tel 03 9747 7777 Fax 03 9747 7700 sales abey com au www abey com au taste of design...

Reviews: