Light Set

Use Light SET for low contrast applications. Use either the push button or

remote input wire procedure to configure the sensor.

Example Applications For Offset Percentages

8%

Recommended for very low contrast applications with stable environmental

conditions.

16%

Recommended for most clear object detection applications in typical machine

industrial environments.

32%

Recommended for high contrast detections such as brown or green bottles, or

opaque objects. This setting tolerates environmental challenges such as

vibrations and dust build-up.

Darkest

Most Light

Output ON

Output OFF

Sensor 
threshold is at 
specified 
offset 
percentage

Figure 2. LIGHT SET sensing mode in dark operate

Table 1: LIGHT SET Push Button Configuration

Setup

Action

Result

Clear the light path to

the reflector.

 

 

Press and hold the push

button 2 to 4 seconds.

 

 

LIGHT SET Configuration Accepted
Green LED Indicator:
 Flashes 3 times.

Green and Amber LED Indicators: Acceptance flash - both LEDs flash 5 times

rapidly in unison.

The sensor returns to Run mode with the new settings.

LIGHT SET Configuration Not Accepted

If there is not enough return signal, the sensor will perform in DARK SET indicated

by the green and amber LED indicators flashing in unison 2 times followed by the

green and amber LED indicators flashing rapidly in unison 5 times.

Dark Set

Dark SET (maximum operating range) is the factory default setting and

provides maximum sensing range, ease of alignment, and reliable

detection of opaque objects. Dark Set provides a fixed threshold

whenever the sensor is taught an obstructed view.

NOTE: The sensor's light spot is made brighter for 60

seconds to assist in aligning the sensor to the reflector.

This is particularly useful for long range applications.

Darkest
(no signal)

Most Light
(saturated
signal)

Output ON

Output OFF

Fixed Threshold

Figure 3. DARK SET sensing mode in dark operate

Table 2: DARK SET Push Button Configuration

Setup

Action

Result

Block the light path to

the reflector.

 

 

Press and hold the push

button 2 to 4 seconds.

 

 

DARK SET Configuration Accepted
Green and Amber LED Indicators:
 Flash 2 times.

Green and Amber LED Indicators: Acceptance flash - both LEDs flash 5 times

rapidly in unison.

The sensor returns to Run mode with the new settings.

DARK SET Configuration Not Accepted
If there is too much return signal, the sensor will perform in LIGHT SET indicated by

the green LED indicator flashing 3 times followed by the green and amber LED

indicators flashing rapidly in unison 5 times.

WORLD-BEAM QS18 Clear Object Detection

 

 