IO-Link Interface
Supports Smart Sensor Profile: Yes
Baud Rate: 38400 bps
Process Data Widths: 32 bits In, 8 bits Out
IODD Files: Provides all programming options of push button and
remote input wire, plus additional functionality. See the IO-Link Data
Reference Guide (p/n 209308) for more details.
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
Construction
Housing: ABS
Window: PMMA
Mounting Torque
Nose Mount: 18 mm mounting nut, 20 Ibf·in (2.3 N·m)
Side Mount: Two M3 screws, 5 Ibf·in (0.6 N·m)
Vibration and Mechanical Shock
All models meet MIL-STD-202G, Method 201A requirements. Also
meets IEC 60947-5-2.
Connections
PVC-jacketed 4-conductor 2 m (6.5 ft) or 9 m (30 ft) unterminated cable,
or 4-pin M12/Euro-style or 4-pin M8/Pico-style quick-disconnect, either
integral or 150 mm (6 in) cable, are available.
Models with a quick disconnect require a mating cordset
Operating Conditions
–20 °C to +70 °C (–4 °F to +158 °F)
95% at +50 °C maximum relative humidity (non-condensing)
Storage Temperature: –65 °C to +125 °C (-85 °F to 257 °F)
Environmental Rating
IEC IP67
Application Notes
If the push button does not appear to be responsive, perform the push
button enable procedure
Certifications
7.3 Dimensions
Pico Models
Cable Models
Euro QD Models
WORLD-BEAM QS18 Expert with IO-Link
www.bannerengineering.com - Tel: + 1 888 373 6767
21