2. Access Dark Set mode and set the sensing condition.
Method
Action
Result
Push Button
Press and hold the push
button 2 to 4 seconds.
DARK SET Configuration Accepted
Green and Amber LED Indicators: Flash 2 times.
Green and Amber LED Indicators: Acceptance flash - both LEDs
flash 5 times rapidly in unison.
The sensor returns to Run mode with the new settings.
DARK SET Configuration Not Accepted
If there is too much return signal, the sensor will perform in LIGHT
SET indicated by the green LED indicator flashing 3 times
followed by the green and amber LED indicators flashing rapidly in
unison 5 times.
Remote Line
Single-pulse the remote
line.
T
Specifications
Supply Voltage
10 V to 30 V dc (10% maximum ripple)
Supply Current (Exclusive of Load Current)
< 25 mA at 15 V
< 40 mA at 24 V
Repeatability
100 µs
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or
short-circuit of output
Output Configuration
Current sourcing (PNP) or current sinking (NPN), depending on model;
Light- or dark-operate selectable; Selectable 30 ms output OFF-delay
Rating: 100 mA max
Off-state leakage current: < 50 µA at 30 V
ON-state saturation voltage: < 1.5 V at 10 mA; < 3 V 100 mA
Output Response Time
Note: Momentary delay on power-up; output does not conduct during this
time
400 µs ON/OFF
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance with
local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to
.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20
5.0
22
3.0
24
2.0
26
1.0
28
0.8
30
0.5
Emitter LED
Visible red, 625 nm
Indicators
Two LEDs (1 green, 1 amber)
Green solid: Indicates power applied and sensor ready
Green flashing: Indicates sensor operating in marginal state, in need of
reconfiguration
Amber solid: Indicates output conducting
Factory Default Settings
Setting
Factory Default
Sensing Mode
Dark Set
Output Logic
Dark Operate
Offset Percent
16%
Push Button
Unlocked
Auto Compensation
Disabled
OFF Delay
Disabled
Mounting Torque
Nose mount: 18 mm mounting nut, 20 lbf·in (2.3 N·m)
Side mount: Two M3 screws, 5 lbf·in (0.6 N·m)
Construction
ABS housing, PMMA window
Connections
PVC-jacketed 4-conductor 2 m (6.5 ft) or 9 m (30 ft) unterminated cable, or
4-pin Euro-style or 4-pin Pico-style quick-disconnect (QD), either integral or
150 mm (6 in) pigtail, are available. QD cordsets are ordered separately.
Operating Conditions
Temperature: –40 °C to +70 °C (–40 °F to +158 °F)
Relative Humidity: 90% at +50 ºC (non-condensing)
Environmental
IEC IP67
Application Notes
If the push button does not appear to be responsive, perform the push
button enable procedure
Certifications
WORLD-BEAM QS18E Clear Object Detection
P/N 194469 Rev. C
www.bannerengineering.com - Tel: +1-763-544-3164
5