Banner U-Gage Ultrasonic Sensor Brochure Download Page 13

13

Banner U-GAGE

®

ultrasonic sensor applications.

Banner U-GAGE

®

ultrasonic sensor applications.

OVERHEAD CRANE GUIDANCE

Product:

T30U

Objective:

The T30 sensor is programmed to signal the crane to stop when

the crane is at a preset distance from a load. Remote TEACH-mode
response settings for the sensor are applied by a system controller.

Sensor Model:

T30UDNB dual-discrete ultrasonic sensor.

Operation:

A T30U sensor mounted above the conveyor may be used to

detect small differences in product height.

U-G

AGE

ANA

LO

G

POW

ER

SIG

NAL

OUT

PUT

DIS

CRE

TE

U-G

AGE

ANA

LOG

POW

ER

SIG

NAL

OU

TPU

T

DIS

CRE

TE

EMPTY COMB VERIFICATION

Product:

T18U 

Objective:

Verify that no hard disks remain on the "comb" following the

rinsing procedure.

Sensor Model:

T18U opposed ultrasonic sensor pair.

Operation:

Originally, the hard disk substrates being rinsed in the comb

rinsing machine were aluminum, and it was easy to tell, using standard
photoelectric sensors, whether any disks remained in the rack following the
rinsing procedure. When clear glass substrates are used, however, an
ultrasonic opposed sensor pair can reliably sense whether any disks remain.
(Photoelectric clear object detection sensors are not recommended for this
application because of the spray rinse.)

ROLL DIAMETER MONITORING

Product:

Q45UR and Flat-Pak Remote Sensor

Objective:

To monitor the payout of a roll of material.

Sensor Model:

Q13C2.0 remote ultrasonic sensor and Q45UR3LIU64C

analog controller.

Operation:

The Flat-Pak remote ultrasonic sensor and its controller work

together to provide roll diameter information to a process controller. The
OPTO-TOUCH

TM

optical touch button is used to program remotely using the

Q45UR controller’s TEACH input.

LIQUID LEVEL MONITORING

Product:

QT50U

Objective:

To monitor the level of liquid in a tank.

Sensor Model:

QT50U sensor with analog output.

Operation:

The narrow beam of the QT50U allows the sensor to be

mounted at the top of a storage tank without its beam reaching the tank wall.
As the liquid level changes, the sensor sends an ongoing signal that is scaled
to represent the current depth of liquid in the tank.

Summary of Contents for U-Gage Ultrasonic Sensor

Page 1: ...U GAGE ULTRASONIC Sensors U GAGE ULTRASONIC Sensors...

Page 2: ...or control and proprietary firmware ensures consistent sensing performance in a wide variety of applications So versatile a single sensor can solve thousands of applications U GAGE technology allows y...

Page 3: ...housing or the turn of a screw Banner ultrasonic sensors offer selectable negative or positive slope for analog sensing Users can also choose from a variety of options for ON OFF or High Low level co...

Page 4: ...kHz Dual Discrete Analog Discrete Analog Dual Discrete Discrete and Analog Discrete Analog Discrete Analog Output Configuration 250 mm 3 m MIN MAX Model Housing Range Custom Sensing Window s Custom Se...

Page 5: ...C Yes 0 02 of sensing distance C No 0 2 of sensing distance C Yes3 Uncompensated 0 2 of sensing distance C Compensated 0 05 of sensing distance C Yes 0 05 of sensing distance C N A IP67 NEMA 6P 20 to...

Page 6: ...ompensation feature providing the highest accuracy across a wide variety of temperature variations Retrosonic mode Reduce inherent ultrasonic dead zone to zero by selecting the QT50U s retrosonic mode...

Page 7: ...e 2 m 6 5 cable 5 pin Euro style QD 5 wire 2 m 6 5 cable 5 pin Euro style QD 10 to 30V dc 10 to 30V dc 10 to 30V dc Bipolar NPN and PNP 0 to 10V dc 4 to 20 mA 0 to 10V dc 4 to 20 mA Straight Right Ang...

Page 8: ...d more secure The T30U allows you to simply push buttons to set accurate custom sized sensing windows and place them anywhere within a 150 mm to 1 m or 300 mm to 2 m range 2 m 6 5 5 pin Euro style QD...

Page 9: ...aled polycarbonate cover Q45U Model Selection Superior diagnostics Three LEDs continuously display programming and operating status by indicating POWER ON OUTPUT OPERATING and SIGNAL STRENGTH A five s...

Page 10: ...direct proportion to the received signal strength to assist in alignment A yellow LED indicates the target is in the operating window limits and OUTPUTS CONDUCTING All models also feature a highly vi...

Page 11: ...in diameter and 30 mm deep Unique signal strength indicator Advanced built in microprocessor analyzes the signal and controls an indicator LED which flashes in direct proportion to the strength of the...

Page 12: ...uid levels in clear containers Sensor Models S18UBAR right angle and S18UIA straight barrel sensors Operation The S18U is ideal for detecting clear objects and measuring liquid levels regardless of co...

Page 13: ...remained in the rack following the rinsing procedure When clear glass substrates are used however an ultrasonic opposed sensor pair can reliably sense whether any disks remain Photoelectric clear obje...

Page 14: ...rogramming of Sensing Window Limits External Thread M30 X 1 5 Mini style QD Connector Hex Nut Supplied 14 mm 0 6 in 79 4 mm 3 13 in 44 5 mm 1 75 in 69 0 mm 2 72 in 87 6 mm 3 45 in 30 0 mm 1 18 in 7 1...

Page 15: ...aded 30 mm swivel black PBT polyester bracket Stainless steel mounting hardware included Style 5 Pin Mini style w Shield 5 Pin Euro style w Shield 4 Pin Euro style Model MBCC2 506 MBCC2 512 MBCC2 530...

Page 16: ...rp 9714 10th Avenue North Minneapolis MN 55441 U S A Phone 763 544 3164 Fax 763 544 3213 bannerengineering com email sensors bannerengineering com PRINTED IN U S A Copyright 2003 Banner Engineering Co...

Reviews: