Banner SureCross Series Manual Download Page 6

I/O

Modbus Holding Register

I/O Type

Units I/O Range

Holding Register
Value

Terminal
Block La-
bels

Gateway

Any Node

Min.
Value

Max. Val-
ue

Min.
(Dec.)

Max.
(Dec.)

4

4

4 + (Node# × 16)

Thermocouple IN 2 °F/°C -1638.3

+1638.4

0

65535

A2+/A2-

5

5

5 + (Node# × 16)

Thermocouple IN 3 °F/°C -1638.3

+1638.4

0

65535

A3+/A3-

6

6

6 + (Node# × 16)

Thermistor IN

°F/°C -1638.3

+1638.4

0

65535

On board

7

7

7 + (Node# × 16)

Reserved

8

8

8 + (Node# × 16)

Device Message

...

15

15

15 + (Node# × 16)

Control Message

16

16

16 + (Node# × 16)

Reserved

The temperature = (Modbus register value) ÷ 20. Temperature values are stored as signed values in the Modbus register. A 0 in the
register is interpreted as 0°; and -32767 (65535 unsigned) in the register (0xFFFF) is interpreted as −1 ÷ 20 = −0.05°.

Replacing the Integrated Battery (DX80 Models)

To replace the lithium "D" cell battery in any integrated housing model, follow these steps.

1. Remove the four screws mounting the face plate to the housing and remove the face plate.
2. Remove the discharged battery and replace with a new battery. Only use a 3.6V lithium battery from Xeno, model number XL-205F.
3. Verify the battery’s positive and negative terminals align to the positive and negative terminals of the battery holder mounted within

the case. The negative end is toward the spring. Caution: There is a risk of explosion if the battery is replaced incorrectly.

4. After replacing the battery, allow up to 60 seconds for the device to power up.

When removing the battery, press the battery towards the negative terminal to compress the
spring. Pry up on the battery’s positive end to remove from the battery holder. Properly dispose
of your used battery according to local regulations by taking it to a hazardous waste collection
site, an e-waste disposal center, or other facility qualified to accept lithium batteries.

As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or expose
them to high temperatures. Do not recharge, crush, disassemble, or expose the contents to wa-
ter.

Replacement battery model number: BWA-BATT-001. For pricing and availability, contact Ban-
ner Engineering.

Specifications

Radio

General

Range

900 MHz: Up to 4.8 kilometers (3 miles) *
2.4 GHz: Up to 3.2 kilometers (2 miles) *

Transmit Power

900 MHz: 21 dBm conducted
2.4 GHz: 18 dBm conducted, less than or equal to 20
dBm EIRP

900 MHz Compliance (150 mW Radios)

Power*

Requirements: 3.6V dc low power option from an inter-
nal battery
Consumption: Less than 1.4 W (60 mA) at 24V dc

Housing

Polycarbonate housing and rotary dial cover; polyester
labels; EDPM rubber cover gasket; nitrile rubber, non-
sulphur cured button covers
Weight: 0.30 kg (0.65 lbs)

 

 

SureCross Temperature Probe with DX80 Node

6

www.bannerengineering.com - tel: 763-544-3164

P/N 156525 rev. -

Summary of Contents for SureCross Series

Page 1: ...ation and a complete list of accessories refer to Banner Engineering s website www bannerengineering com surecross Models Description Frequency I O BWA TPROBE 001 Wireless DX80 Node and temperature pr...

Page 2: ...rolling other devices or performing calculations Host connected systems can contain up to 15 Nodes when using Rotary Dial Addressing Mode or 47 Nodes when using Extended Addressing Mode within a singl...

Page 3: ...ing without damaging the ribbon cable or the pins the cable plugs into 3 Gently unplug the ribbon cable from the board mounted into the bottom housing For integrated battery models no ribbon cable and...

Page 4: ...DIP switch to the ON position Thermocouple Type Use DIP switches 5 6 7 and 8 to select the thermocouple type The default position is the OFF position for all switches setting the thermocouple to a J t...

Page 5: ...es are communicating properly A Node will not sample its inputs until it is communicating with the Gateway to which it is bound When testing communication between the Gateway and Node all radios and a...

Page 6: ...re is a risk of explosion if the battery is replaced incorrectly 4 After replacing the battery allow up to 60 seconds for the device to power up When removing the battery press the battery towards the...

Page 7: ...eport Rate 16 seconds Accuracy 0 1 of full scale reading 0 8 C Resolution 0 1 C 24 bit A D converter Thermistor used for CJC Model BWA THERMISTOR 001 Accuracy 0 4 C 10 to 50 C Up to 0 8 C 40 to 85 C R...

Page 8: ...ent Banner Engineering Corp will repair or replace free of charge any product of its manufacture which at the time it is returned to the factory is found to have been defective during the warranty per...

Reviews: