background image

Specifications

Radio

General

Radio Range

900 MHz: Up to 9.6 kilometers (6 miles) *
2.4 GHz: Up to 3.2 kilometers (2 miles) *

Radio Transmit Power

900 MHz: 30 dBm conducted (up to 36 dBm EIRP)
2.4 GHz: 18 dBm conducted, less than or equal to 20
dBm EIRP

900 MHz Compliance (1 Watt Radios)

FCC ID UE3RM1809: This device complies with FCC
Part 15, Subpart C, 15.247
IC: 7044A-RM1809

2.4 GHz Compliance

FCC ID UE300DX80-2400 - This device complies with
FCC Part 15, Subpart C, 15.247
ETSI/EN: In accordance with EN 300 328: V1.7.1
(2006-05)
IC: 7044A-DX8024

Spread Spectrum Technology

FHSS (Frequency Hopping Spread Spectrum)

* With the 2 dB antenna that ships with the product. High-gain an-
tennas are available, but the range depends on the environment
and line of sight. To determine the range of your wireless network,
perform a Site Survey.

Power*

Requirements: +10 to 30V dc (For European applica-
tions: +10 to 24V dc, ± 10%) on the brown wire, or 3.6
to 5.5V on the gray wire
900 MHz Consumption: Gray wire (3.8V) at 650 mW;
Brown wire (12V) at 900 mW
2.4 GHz Consumption: Gray wire (3.8V) at 120 mW;
Brown wire (12V) at 250 mW

Housing

Polycarbonate housing and rotary dial cover; polyester
labels; EDPM rubber cover gasket; nitrile rubber, non-
sulphur cured button covers
Weight: 0.26 kg (0.57 lbs)
Mounting: #10 or M5 (SS M5 hardware included)
Max. Tightening Torque: 0.56 N·m (5 lbf·in)

Antenna Connection

Ext. Reverse Polarity SMA, 50 Ohms
Max Tightening Torque: 0.45 N·m (4 lbf·in)

Interface

Indicators: Two bi-color LEDs
Buttons: Two
Display: Six character LCD

Wiring Access

One 5-pin Euro-style male connector

* For European applications, power the DX80 from a Limited Pow-
er Source as defined in EN 60950-1.

Notice: This equipment must be professionally installed. The output power must be limited, through the use of firmware or a hardware
attenuator, when using high-gain antennas such that the +36 dBm EIRP limit is not exceeded.

Communication

Environmental

Hardware (MultiHop RS-485)

Interface: 2-wire half-duplex RS-485
Baud rates: 9.6k, 19.2k (default), or 38.4k via DIP
switches; 1200 and 2400 via the MultiHop Configura-
tion Tool
Data format: 8 data bits, no parity, 1 stop bit

Packet Size (MultiHop)

900 MHz: 175 bytes (85 Modbus registers)
2.4 GHz: 125 bytes (60 Modbus registers)

Intercharacter Timing (MultiHop)

3.5 milliseconds

Rating

IEC IP67; NEMA 6; (See UL section below for any ap-
plicable UL specifications)

Operating Conditions

Operating Temperature: −40 to +85° C (Electronics);
−20 to +80° C (LCD)
Operating Humidity: 95% max. relative (non-condens-
ing)
Radiated Immunity: 10 V/m, 80-2700 MHz
(EN61000-6-2)

Shock and Vibration

IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz

Refer to the SureCross

®

 MultiHop product manual, Banner p/n

151317, for installation and waterproofing instructions. Operating
the devices at the maximum operating conditions for extended pe-
riods can shorten the life of the device.

SureCross MultiHop Data Radio

 

 

P/N 148345 Rev. B

www.bannerengineering.com - tel: 763-544-3164

7

Summary of Contents for SureCross DX80DR2M-H

Page 1: ...0 to 30V dc or 3 6 to 5 5V dc low power option 900 MHz ISM Band 250 mW or 1 Watt DIP switch selectable DX80DR2M H 2 4 GHz ISM Band 65 mW 100 mW EIRP WARNING Not To Be Used for Personnel Protection Nev...

Page 2: ...ata packets from its parent then re transmits the data packet to the children within the repeater s network The incoming packet of information is re transmitted on both the radio link and the local se...

Page 3: ...e End User Edition 155289 Configuring the DIP Switches Before making any changes to the DIP switch positions disconnect the power For devices with batteries integrated into the housing remove the batt...

Page 4: ...ata communication is packet based and not specific to any protocol The application layer is responsible for data integrity For one to one data radios it is possible to enable broadcast acknowledgement...

Page 5: ...change all three jumper positions The jump ers are shown configured for RS 485 communication factory default position Set the MultiHop Radio Slave ID On a MultiHop radio use the rotary dials to set th...

Page 6: ...right most characters in the string Within a given Modbus register the upper byte contains the ASCII character that goes to the right of the character in the lower byte Address 4xxxx Name Format 6401...

Page 7: ...ghtening Torque 0 45 N m 4 lbf in Interface Indicators Two bi color LEDs Buttons Two Display Six character LCD Wiring Access One 5 pin Euro style male connector For European applications power the DX8...

Page 8: ...g Corp All rights reserved Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following the date of...