WARNING:

• Risk of electric shock
• Use extreme caution to avoid electrical shock. Serious injury or death could result.
• Always disconnect power from the safety system (for example, device, module, interfacing, etc.),

guarded machine, and/or the machine being controlled before making any connections or
replacing any component. Lockout/tagout procedures might be required. Refer to OSHA
29CFR1910.147, ANSI Z244-1, or the applicable standard for controlling hazardous energy.

• Make no more connections to the device or system than are described in this manual. Electrical

installation and wiring must be made by a Qualified Person

2

 and must comply with the applicable

electrical standards and wiring codes, such as the NEC (National Electrical Code), ANSI NFPA79,
or IEC 60204-1, and all applicable local standards and codes.

2.3 Output Signal Switching Devices (OSSDs) and External Device
Monitoring (EDM)

The SSA-EB1PLx-0Dx is able to detect faults on OSSD1 and OSSD2. These faults include short circuits to +24 V DC and 0

V, and between OSSD1 and OSSD2.
Both OSSD outputs must be connected to the machine control so that the machine's safety-related control system

interrupts the circuit or power to the machine primary control element(s) (MPCE), resulting in a non-hazardous condition.
Final switching devices (FSDs) typically accomplish this when the OSSDs go to an OFF state.
Refer to the output specifications and these warnings before making OSSD output connections and interfacing the SSA-

EB1PLx-0Dx to the machine.

WARNING:

• Interfacing both output signal switching devices (OSSD)
• Failure to follow these instructions could result in serious injury or death.
• Unless the same degree of safety is maintained, never wire an intermediate device(s) (PLC, PES,

PC) between the safety module outputs and the master stop control element it switches such
that a failure causes a loss of the safety stop command or the failure allows the safety function to
be suspended, overridden, or defeated.

• Connect both OSSD outputs to the machine control so that the machine’s safety-related control

system interrupts the circuit to the machine primary control element(s), resulting in a non-
hazardous condition.

WARNING:

• Interfacing OSSD Outputs to Machine Inputs
• Failure to properly interface the OSSD Outputs to the guarded machine could result in serious

injury or death.

• To ensure proper operation, the Banner device output parameters and machine input parameters

must be considered when interfacing the Banner device OSSD outputs to machine inputs. Design
the machine control circuitry so that the maximum load resistance value is not exceeded and the
maximum specified OSSD Off-state voltage does not result in an On condition.

External device monitoring (EDM) is a function used to monitor the state of the external, positively guided (mechanically

linked) machine control contacts (Final Switching Devives (FSD) and/or MPCEs). The SSA-EB1PLx-0Dx does not include the

EDM function. As a result, the SSA-EB1PLx-0Dx should be used with an external safety monitoring device that monitors the

status of the two SSA-EB1PLx-0Dx OSSDs and is capable of providing the EDM function.
Examples of appropriate external safety monitoring devices include the Banner SC10-2ro Safety Controller.

WARNING:

• The SSA-EB1PLx-0Dx does not have external device monitoring (EDM).
• If EDM is required for the application, it must be implemented in the external control.

2

A person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and
experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work.

SSA-EB1PLx-0Dx Series Lighted Emergency Stop Button with ISD

 

 

6

www.bannerengineering.com - Tel: + 1 888 373 6767

 

Summary of Contents for SSA-EB1PL 0D Series

Page 1: ...SSA EB1PLx 0Dx Series Lighted Emergency Stop Button with ISD Instruction Manual Original Instructions 215157 Rev A 3 August 2020 Banner Engineering Corp All rights reserved 215157...

Page 2: ...Using the Quick Disconnect QD 8 2 5 Checkout 10 2 6 Resetting the Inputs 10 2 7 In Series Diagnostic ISD Information 11 2 8 Installing the Silicone Cover 11 3 Specifications 12 3 1 Dimensions 12 4 Ac...

Page 3: ...SSA EB1PLXR 0DECQ8 None SSA EB1PLGR 0DECQ8 Green SSA EB1PLYR 0DECQ8R Yes Yellow SSA EB1PLXR 0DECQ8R None SSA EB1PLGR 0DECQ8R Green SSA EB1PLYR 0DED1Q8 Flush No Yellow SSA EB1PLXR 0DED1Q8 None SSA EB1P...

Page 4: ...more devices to the same safety module controller in series Connecting devices in parallel defeats the switch contact monitoring ability of the module and creates an unsafe condition that could resul...

Page 5: ...s The device is intended for indoor use only and must not be affected by environmental conditions Install the device so that operation is not impeded but protected against inadvertent operation for ex...

Page 6: ...master stop control element it switches such that a failure causes a loss of the safety stop command or the failure allows the safety function to be suspended overridden or defeated Connect both OSSD...

Page 7: ...ro The SSA EB1PLx 0Dx Series Lighted Emergency Stop Button with ISD can be connected in series or individually to a compatible Banner XS26 2 or SC10 2ro Safety Controller See the XS26 2 SC10 Safety Co...

Page 8: ...Connect the female 4 pin M12 Euro style cable to the male 4 pin M12 Euro style of the series connection t adapter SI RFA TS 2 If a manual reset model emergency stop device is used connect the female 8...

Page 9: ...ay be needed refer to Figure 11 on p 10 For using ISD information to monitor the individual device voltages see In Series Diagnostic ISD Information on p 11 There are two options to connect an additio...

Page 10: ...e contamination Replace the switch and or appropriate components when any parts or assemblies are damaged broken deformed or badly worn or if the electrical mechanical specifications for the environme...

Page 11: ...ce information to be loaded into the machine control system To interpret this information Banner diagnostic modules are available including the SI RF DM1 Diagnostic Module and the SC10 2roe Safety Con...

Page 12: ...of following ISD devices Housing Button Flush mount models Polycarbonate Polyamide 10 or M5 M5 hardware included Max tightening torque 0 56 N m 5 in lbf Housing Button 30 mm models Polycarbonate Poly...

Page 13: ...wn silicone cover SSA EB1P ECWC DTM1 102 1 4 02 109 5 4 31 65 2 56 65 2 56 33 1 30 14 7 0 58 80 3 3 16 80 8 3 18 4X 5 5 0 22 10 2 0 40 Figure 14 Flush mount models SSA EB1PLx 0Dx Series Lighted Emerge...

Page 14: ...lack 5 Gray MQDC1 506 2 m 6 5 ft MQDC1 515 5 m 16 4 ft MQDC1 530 9 m 29 5 ft MQDC1 506RA 2 m 6 5 ft Right Angle 32 Typ 1 26 30 Typ 1 18 14 5 0 57 M12 x 1 MQDC1 515RA 5 m 16 4 ft MQDC1 530RA 9 m 29 5 f...

Page 15: ...ft MQDEC 420RS 6 10 m 20 ft MQDEC 430RS 9 14 m 30 2 ft MQDEC 450RS 15 2 m 49 9 ft 8 Pin Threaded M12 Euro Style Cordsets Double Ended Model 8 pin 8 pin 4 Length Style Dimensions Pinout DEE2R 81D 0 3 m...

Page 16: ...SI RFA DM1 SI RF Diagnostic Module with 8 digital outputs and 1 diagnostic circuit Interfaces IO Link USB 2 0 SSA EB1P ECWC FDA grade silicone cover 4 4 Safety Controllers Safety Controllers provide a...

Page 17: ...r external device monitoring is required in the application See datasheet p n 141249 for more information Model Description UM FA 9A 3 normally open N O redundant output 6 amp contacts UM FA 11A 2 nor...

Page 18: ...l X Double flash red OFF Faults that do not immediately compromise the safe operation of the emergency stop device for example safety output to external potential crosswire short safety output result...

Page 19: ...Input 2 1 0 ISD device input 2 is on Local reset expected 1 0 An ISD device with the latch feature requires a reset Operating voltage warning 1 0 Voltage to the ISD device is at the limit of specific...

Page 20: ...the Banner product THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PART...

Reviews: