Figure 5. 300 mm Pigtail with M12/Euro-style QD
Figure 6. RD Connection with 8-wire Flying Lead
Cordset
Figure 7. RD Connection with Double-ended RD
Cordset
3.3.6 Cascading
Up to four sensor pairs (any length or resolution) can be combined into one system. The cascade system automatically
configures at power up when the terminator plug is installed (pre-installed from factory) or when a standard sensor pair or
an interfacing cordset is used at the end of the series. Double-ended DELS-11xE cordsets are required for connecting
sensors in a cascade.
3.3.7 EZ-LIGHT
®
Indication
EZ-SCREEN LS cascading models have the ability to connect and remotely locate an EZ-LIGHT or other indicator using a
DELSEF-4xD cordset. Solid-state current sourcing (PNP) outputs (24 V dc at 100 mA) allow for the connection of remote
indicators or other devices for non-safety status information that includes OSSDs ON or OSSDs OFF/Lockout (flashing).
Additionally, EZ-LIGHT model EZLSA-K30LGR (patent pending) is designed to mount directly to the end of a cascade
receiver via the cascade RD connector. The EZLSA-K30LGR provides a replaceable integral solution with a bright 360° red/
green indication.
For the EZ-SCREEN LS standard (non-cascade) 8-pin pigtail QD models, a CSB-M128..M1281 splitter cable and optional
DEE2R-8..D double-ended cables can be used with specific models of EZ-LIGHTs at the machine interface connection. The
EZ-LIGHT can be remotely mounted on the machine frame or another convenient mounting surface and provides clear,
360° indication of the EZ-SCREEN LS receiver’s OSSD output status.
See
on page 92 for both standard and cascade solutions.
Figure 8. EZ-SCREEN LS with M18 EZ-LIGHT
Figure 9. EZ-SCREEN LS with EZLSA-K30LGR
EZ-LIGHT
Figure 10. EZ-SCREEN LS with TL50 EZ-LIGHT
EZ-SCREEN
®
LS Safety Light Screen
22
www.bannerengineering.com - Tel: +1.763.544.3164