background image

Hinge Switches – 

SI-HG63 Series

     

P/N 129465

 

Banner Engineering Corp.

 • Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

 

Important

 

Information

 Regarding the Use of Safety Switches

In the United States, the functions that Banner safety switches are intended to perform are regulated by the Occupational Safety and 
Health Administration (OSHA). Whether or not any particular safety switch installation meets all applicable OSHA requirements depends 
upon factors that are beyond the control of Banner Engineering Corp. These factors include the details of how the safety switches are 
applied, installed, wired, operated, and maintained.
Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenance instructions. This 
information is found in the instruction manual packaged with each safety switch. In addition, we suggest that any questions regarding 
the use or installation of safety switches be directed to the factory applications department at the telephone numbers or address shown 
below.
Banner Engineering Corp. recommends that safety switches be applied according to the guidelines set forth in international (ISO/IEC) 
standards listed below. Specifically, Banner Engineering Corp. recommends application of these safety switches in a configuration which 
meets safety category 4, per ISO 13849-1 (EN954-1).
In addition, the user of Banner safety switches has the responsibility to ensure that all local, state, and national laws, rules, codes, and 
regulations relating to the use of Banner safety switches in any particular application are satisfied. Extreme care is urged that all legal 
requirements have been met and that all installations and maintenance instructions are followed.

U.S. Regulations Applicable to Use of Banner Safety Switches

  OSHA Code of Federal Regulations: Title 29, Parts 1900 to 1910 
     

 

 

Available from: 

Superintendent of Documents 

     

 

 

 

 

Government Printing Office 

     

 

 

 

 

P.O. Box 371954 

     

 

 

 

 

Pittsburgh, PA 15250-7954 

     

 

 

 

 

Tel: 202-512-1800

U.S. Standards Applicable to Use of Banner Safety Switches 

  ANSI B11 

 

“ Standards for Construction, Care, and Use of Machine Tools” 

Available from: 

Safety Director 

 

 

AMT—The Association for Manufacturing Technology 

 

 

7901 Westpark Drive 

 

 

McLean, VA 22102 

 

 

Tel: 703-893-2900

Applicable European and International Standards

  ISO 12100-1/-2   

“Safety of Machinery—Basic Concepts, General Principles for Design” 

  (EN 292-1/-2)
  ISO 13852 (EN 294) 

“Safety of Machinery—Safety Distances to Prevent Danger Zones Being Reached by the Upper Limbs”

  ISO 13853 (EN 811) 

“Safety of Machinery—Safety Distances to Prevent Danger Zones Being Reached by the Lower Limbs”

  ISO 13849-1 (EN 954-1)  “Safety of Machinery—Safety Related Parts of Control Systems”
  ISO 13855 (EN 999) 

“ Safety of Machinery—The Positioning of Protective Equipment in Respect to Approach Speeds of Parts of 

the Human Body”

  ISO 14119 (EN 1088) 

“Safety of Machinery—Interlocking Devices Associated with Guards—Principles for Design and Selection”

  IEC/EN 60204-1  

“Safety of Machinery—Electrical Equipment of Machines”

  IEC/EN 60947-5-1 

“Low Voltage Switchgear—Electromechanical Control Circuit Devices”

     

 

Available from: 

Global Engineering Documents 

     

 

   

 

15 Inverness Way East 

     

 

   

 

Englewood, CO 80112-5704 

     

 

   

 

Phone: 1-800-854-7179 

     

 

   

 

Fax: 303-397-2740

Application Assistance

Toll Free

1-888-3-SENSOR (1-888-373-6767)

Email:

 

[email protected]

Address

9714 Tenth Avenue North

 

Minneapolis, MN 55441

Summary of Contents for SI-HG63FQDR

Page 1: ...operly interfaced or used with an appropriate controller two SI HG63 switches on an individual gate or guard can achieve safety category 4 per ISO 13849 1 EN 954 1 Typical applications include Hinged covers and guards to machines Hinged doors and gates in safety fencing systems Modular aluminum framing NOTE Terminals 33 and 34 are non safety Model Housing Style QD Connection Contact Configuration ...

Page 2: ... satisfied Extreme care is urged that all legal requirements have been met and that all installations and maintenance instructions are followed U S Regulations Applicable to Use of Banner Safety Switches OSHA Code of Federal Regulations Title 29 Parts 1900 to 1910 Available from Superintendent of Documents Government Printing Office P O Box 371954 Pittsburgh PA 15250 7954 Tel 202 512 1800 U S Stan...

Page 3: ...an end stop The operating angle of the switch must be limited by outer end stops WARNING It must not be possible for personnel to reach any hazard point through an opened guard or any opening before hazardous machine motion has completely stopped Please reference OSHA CFR 1910 217 and ANSI B11 standards see page 2 for information on determining safety distances and safe opening sizes for your guar...

Page 4: ...in the screws for later reuse 2 Insert a flat blade screwdriver between the hinge housing and the plastic plug to gently pry the plastic plugs out Retain the plastic plugs for later reuse Figure 3b 3 Remove the hinge portion from the switch Lift the red plastic washer from the switch Discard the plastic washer it cannot be reused Figures 3c and 3d 4 Align the switch cylinder arrow with mark A on t...

Page 5: ...Hinge Switches SI HG63 Series P N 129465 Banner Engineering Corp Minneapolis MN U S A www bannerengineering com Tel 763 544 3164 h Figure 3 Relocating the switch point setting a b c d e g f SW8 ...

Page 6: ...age Signs of tampering or defeat to the switch or to the wiring interface to the machine A designated person is identified in writing by the employer as being appropriately trained to perform a specified checkout procedure Repairs Do not attempt any repairs to the switch It contains no field replaceable components Return the switch to the factory for warranty repair or replacement If it becomes ne...

Page 7: ... Blow Recommended external fusing or overload protection Force Exerted by Guard per Switch Axial and Radial 1200 N 264 lbf max Operating Range 0 to 270 Wire Connections 6 pin Micro style quick disconnect QD fitting Cordsets are ordered separately see page 8 Construction Hinge X22CrNi 17 Switch PBT Environmental Rating NEMA 4 IEC IP67 acc IEC EN60529 Operating Conditions Temperature 25 to 70 C 13 t...

Page 8: ... returned to the factory during the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either expressed or implied Accessories Blank Hinge Model Description Dimensions SI HG63A Blank hinge same mechanical specifications as SI HG63 Series hinge switches but without the safety switch componen...

Reviews: