Features

•   Reliably detects vehicles and trains based on frequency-modulated continuous-wave 

(FMCW) radar technology

•   Detects objects up to 7.2 m (24') away using a fixed background reference target up 

to 8 m (26') away

•  Detection is unaffected by wind or changing air temperatures
•  Easy to set up using sealed push button or remote wire
•   Operates in Industrial, Scientific, and Medical (ISM) telecommunication band; no 

special license required

• 15 to 30V dc operation
•  Rugged IP67 housing for harsh environments

Models

Models*

Sensing Range

Cable

Telecom Approval

Output

QT50R

Objects:

 

0.5 to 7.2 m (1.6' to 24')

Background:

 

4 to 8 m (13' to 26')

5-wire, 2 m (6.5') cable

ETSI/EN 300 440 

(EU except 

UK and France)

Bipolar NPN and PNP

QT50RQ

5-pin Euro-style integral QD

QT50RUS

5-wire, 2 m (6.5') cable

FCC Part 15 

(USA)

QT50RUSQ

5-pin Euro-style integral QD

* For 9 m cable, add suffix “

W/30

” to the model number of the cabled sensor (e.g., 

QT50R W/30

). A QD model requires a mating cable. See page 7.

Summary of Contents for R-GAGE QT50R Series

Page 1: ...requency modulated continuous wave FMCW radar technology Detects objects up to 7 2 m 24 away using a fixed background reference target up to 8 m 26 away Detection is unaffected by wind or changing air temperatures Easy to set up using sealed push button or remote wire Operates in Industrial Scientific and Medical ISM telecommunication band no special license required 15 to 30V dc operation Rugged ...

Page 2: ... determine the distance from the sensor to the vehicle based on the time delay of the return signal The sensor is configured to operate like a retroreflective photoelectric sensor See Figure 3 Figure 3 Threshold automatically placed at 90 of distance to background target that is taught NOTE The MODE button on this model is not functional Background Range 4 to 8 m 13 to 26 Dead Zone 0 5 m 1 6 Backg...

Page 3: ...gramming procedure in the table below General Notes on Programming Once the sensor enters TEACH mode it will default to the previous settings and exit TEACH mode after one minute To exit TEACH mode and return to the previous settings push and hold the TEACH push button or pulse the remote line for more than two seconds 4 Procedure Result Push Button Remote Line 0 02 sec T 0 8 sec Programming Mode ...

Page 4: ...sensor so the center of the beam strikes the corner of the tunnel beyond the far rail as shown in Figure 4 2 Make sure the area between the sensor and the background is clear and press the TEACH button until the Output LEDs turn ON red 3 Align the sensor The red Signal LED will flash faster as alignment improves solid ON is best 4 Press the TEACH button again The Output LEDs turn OFF and the red S...

Page 5: ... programming button for setting background reference Operating Temperature 20 to 55 C 4 to 131 F Environmental Rating IEC IP67 NEMA 6 Connections 2 m 6 5 or 9 m 30 5 conductor shielded PVC jacketed attached cable or integral 5 pin Euro style QD Certifications and ETSI EN 300 440 or FCC Part 15 depending on model Status Indicators Power LED Indicates OFF Power is OFF ON Green Power is ON Signal LED...

Page 6: ...d that the shield wire be connected to earth ground or dc common Shielded cordsets are recommended for all QD models bk gy bn bu wh 15 30V dc shield 0 2V dc Load 1 Load 2 Dimensions 38 1 mm 1 50 46 1 mm 1 82 R45 0 mm R1 77 66 0 mm 2 60 84 2 mm 3 31 33 0 mm 1 30 37 0 mm 1 46 74 1 mm 2 92 50 8 mm 2 00 50 8 mm 2 00 19 7 mm 0 78 37 0 mm 1 46 M30 X 1 5 ISO 6g 4X Ø4 4 mm Ø 0 17 34 2 mm 1 35 Cabled Model...

Page 7: ...it clamp with swivel black reinforced thermoplastic polyester Stainless steel hardware included SMB30MM 30 mm 11 gauge stainless steel bracket with curved mounting slots for versatile orientation Clearance for M6 1 4 hardware 50 8 mm 2 00 58 7 mm 2 31 66 5 mm 2 62 30 0 mm 1 18 30 x 1 5 mm internal thread 29 0 mm 1 14 12 7 mm 0 50 35 1 mm 1 38 35 1 mm 1 38 69 9 mm 2 75 7 1 mm 0 28 x 90 2 Slots R 25...

Page 8: ...g Corp warrants its products to be free from defects for one year Banner Engineering Corp will repair or replace free of charge any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either...

Reviews: