5.1 Light Operate/Dark Operate ........................................................................................................................................................................ 17
5.2 Complementary Output ............................................................................................................................................................................... 17
5.3 Set ............................................................................................................................................................................................................... 17
5.4 Laser On/Laser Off ...................................................................................................................................................................................... 17
5.5 Sync Master/Slave ...................................................................................................................................................................................... 17
5.6 Pulse Frequency Modulation (PFM) Output ................................................................................................................................................ 18
The output of Channel 2 can be pre-configured to light operate or dark operate and is independent of Channel 1. The teach
method of both channels is the same.
See
for instructions on teaching Channel 2.
In light operate, the output turns on when a target is present inside the switch points of the sensor.
In dark operate, the output turns off when a target is present inside the switch points of the sensor.
Output 2 switches opposite of Output 1.
Allows the
Q5Z Global
to use its remote input.
.
The laser can be controlled to either turn on or off depending on the setting by activating the remote input wire.
.
A maximum of two
Q5Z Global
sensors may be used together in a single sensing application.
To eliminate crosstalk between the two sensors, configure one sensor to be the master and one to be the slave, then connect
the white wires together. In this mode, the sensors alternate taking measurements and the response speed doubles.
NOTE: The master sensor and the slave sensor must be configured for the same Response Speed and
Gain and Sensitivity settings. The master sensor and slave sensor must share a common power source.
Channel 2 Output or Function
Chapter 5
Light Operate/Dark Operate
5.1
Complementary Output
5.2
Set
5.3
Laser On/Laser Off
5.4
Sync Master/Slave
5.5
© Banner Engineering Corp.
Summary of Contents for Q5Z
Page 4: ...Blank page 4...
Page 8: ...Blank page 8...
Page 16: ...Blank page 16...
Page 26: ...Blank page 26...
Page 34: ...Blank page 34...
Page 38: ...Blank page 38...
Page 41: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...