Q5Z Global Laser Measurement Sensor With IO-Link Instruction Manual
15
Chapter Contents
Use the remote input to program the sensor remotely.
Remote input is available when the Channel 2 Function is configured to Remote TEACH input.
The remote input provides limited programming options and is configured to be Active High (PNP).
For Active High (PNP), connect the white wire to 24 V DC with a remote switch connected between the wire and 24 V DC.
Pulse the remote input according to the diagram and the instructions provided in this manual.
The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds.
Exit remote programming modes by activating the remote input for longer than 2 seconds.
1x
Starts selected Teach
(same function as pressing Teach Button for > 2 sec)
1x
Second pulse completes Teach (Two-point, Dynamic Teach and Dual Mode only)
0.04 seconds < T < 0.8 seconds
Timing between Pulse groups > 1 second
Pulse Timing (T)
Input Wire Function = Set
Remote TEACH input per
wiring diagram
8x
Reset to Factory Defaults
(maintain remote input = SET)
Remote
Input
Follow the instructions below to reset the
Q5Z Global
to factory defaults using Remote Input.
Eightpulse the remote input to apply the factory defaults and return to Run mode.
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
NOTE:
The input wire function remains at remote teach input.
Remote Input
Chapter 4
Remote Input Map
Figure 17.
Reset to Factory Defaults Using the Remote Input
4.1