Banner M-GAGE Installation Instructions Manual Download Page 2

Figure 3. M-GAGE receiver window

1. Point the optical commissioning device at the receiver.

The red arrow is pointing to the receiver window.

2. Click and hold the optical commissioning device's button until the red/green LED in the center of the M-GAGE lights up,

about five seconds.
When the device wakes up, the LEDs flash according to the LED table.

To return the M-GAGE back to its deep sleep mode, click and hold the optical commissioning button until the red LED in the center

of the M-GAGE stops blinking, about five seconds.

Bind the M-GAGE to the DXM Controller

Bind the M-GAGE Node to the DXM Controller before burying the M-GAGE.
To bind the M-GAGE Node to the DXM Controller, we have DXM Controller, M-GAGE, and the optical commissioning device (

BWA-

MGFOB-001

) available.

1. Set the DXM Controller's ISM radio to operate at 250 mW.

Before the M-GAGE Node can bind to the DXM Controller, the DXM Controller's ISM radio must be set to operate at 250
mW.
a) On the DXM: Use the up and down arrows to scroll to the 

System Config

 menu. Press 

ENTER

.

b) Scroll to the 

ISM Radio

 menu and press 

ENTER

.

c) Scroll to 

RF Power

 and press 

ENTER

.

d) Scroll to 

900 0.25W

 and press 

ENTER

.

e) Press 

ENTER

 when the DXM indicates that it needs to restart.

The DXM restarts and returns to the main menu.

2. On the DXM: Scroll down the menu options to 

ISM Radio

 and press 

ENTER

.

3. Select 

Binding

 and press 

ENTER

.

4. Use the arrow buttons to scroll to Node 1 and press 

ENTER

.

Each Node within the radio network must have a unique Node ID. This example is referring to Node 1, but the Node ID can
be any valid ID.
The DXM enters binding mode with Node 1.

5. On the M-GAGE Node: Verify the M-GAGE is awake. If it is not awake, see 

Wake the M-GAGE from Deep Sleep Mode 

on

page 1.

6. Hold the optical commissioning device to the M-GAGE's receiving window and click the button three times.

Figure 4. Triple-click the button to put the M-GAGE into binding mode

The LED in the center of the M-GAGE Node flashes an alternating red and green. When the both LEDs both are on, the
binding process has started. The final binding process occurs when both LEDs flash in unison four times. After binding is
complete, the M-GAGE Node automatically exits the binding process and reboots.

7. On the DXM: After the M-GAGE Node is bound to the DXM, press the DXM's 

BACK

 button to exit binding mode.

 

 