Specifications
Supply Voltage and Current
250V ac/dc
Impulse Withstand Voltage
3-position switch:
2.5 kV
Momentary pushbutton:
1.5 kV
Output Contact Ratings
See table below.
Rated Thermal Current (Ith):
2.5 A*
*For the following operating temperatures:
40°C < 50°C:
2 A ( 4 contacts under load)
50°C < 60°C:
1.5 A ( 3 contacts under load)
Contact Resistance
100 mohm max.
Insulation Resistance
Live to dead metal parts:
100 Mohm min.
Positive to negative live parts:
100 Mohm min.
Recommended Wire/Cable Size
Wire:
0.14 to 1.5 mm² (25 AWG to 16 AWG)
Cable:
ø 7 to 13 mm
M20 conduit
Short Circuit Protection
250V / 10A fast blow fuse (IEC 60127-1)
Conditional short circuit current:
50 A (250V)
Vibration Resistance
Operating extremes:
5 to 55 Hz, half amplitude 0.5
mm minimum
Damage limits:
16.7 Hz, half amplitude 1.5 mm mini-
mum
Shock Resistance
Operating extremes:
150 m/s² (15 G)
Damage limits:
1,000 m/s² (100 G)
Direct Opening
(Terminals 5 and 6 models ED1G-L21SM-1N and
ED1G-L21SMB-1N)
Actuating Force:
70 N minimum
Travel:
4.7 mm minimum
Date code format:
YYWWX:
2-digit year, 2-digit week, "X” internal code
Mechanical Life
Positions 1 & 2 only:
1,000,000 operations minimum
Positions 1, 2 & 3:
100,000 operations minimum
Operating frequency:
1,200 operations per hour max-
imum
Electrical Life
100,000 operations minimum at rated load
Pollution Degree
3
Terminal Pulling Strength
20 N minimum
Terminal Screw Torque
0.5 to 0.6 Nm
Operating Conditions (indoor use only)
Temperature:
–10° to +60° C (no freezing)
Humidity:
45 to 85% RH max. (no condensation)
Storage Temperature:
–40° to +80° C (no freezing)
Construction
Polyamide housing and cable gland, NBR/PVC poly-
blend rubber grip switch boot; model
ED1G-L21SM
-1N
meets IP66; other models meet IP65
Applicable Standards
Design Standards:
IEC 60947-5-1, EN 60947-5-1, JIS
C8201-5-1, UL 508, CSA C22.2 No. 14, GS-ET-22
Application Standards:
ISO 12100/EN ISO 12100,
IEC 60204-1/ EN 60204-1, ISO 11161/EN ISO11161,
ISO10218-1/EN ISO10218-1, ANSI/RIA/ISO 10218-1,
ANSI NFPA 79, ANSI/RIA R15.06, ANSI B11.19, ISO
13849-1/EN ISO 13849-1
Certifications
Ratings approved by Safety Agencies
TÜV rating:
AC-15 250V ac 0.5A; DC-13 125V dc
0.1A; Applicable EC Directives: LOW Voltage Directive
(2006/95/EC), Machinery Directive (2006/42/EC); Ap-
plicable EC Standard(s): EN60947-5-1, GS-ET-22
UL, c-UL rating:
250V ac, 0.5A Pilot Duty; 125V dc,
0.1A Pilot Duty, Ambient Tempe40°C, Environ-
mental Rating Type 4X, Indoor Use Only. UL has only
investigated this device for shock and fire to UL508.
ED1G Enabling Switch
10
www.bannerengineering.com - tel: 763-544-3164
P/N 151822 Rev. B