Output ON and OFF conditions can be reversed using the LO/DO switch.
The Output ON and OFF conditions can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch or through
the program interface for the dual output model.
Window SET and Manual Adjust
Moves sensing window center value up or down to make adjustments
• Slide Mode switch to ADJ to enter Adjust mode
• Press "+" to increase; press "-" to decrease
◦
GREEN display shows the sensing window center value
◦
2 seconds after adjustment, the GREEN display will flash 3 times to confirm
• Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Window SET:
Note: TEACH Selection must be programmed to wind SEt.
1. Enter Adjust Mode
Method
Action
Result
SET Button 11
Set Mode switch to ADJ
Display: Red - Signal Level; Green -
Threshold
Remote Input 12
No action required; sensor is ready for
Window SET method
2. SET Sensing Condition
Method
Action
Result
SET Button
•
Present sensing condition
•
Click the SET rocker button
Threshold Condition Accepted
Displays read "wInd SEt" then alternate
"PASS" with % Offset13; Sensor
returns to Adjust mode
Threshold Condition Not Accepted
Displays read "wInd SEt" then alternate
"FAIL" with minimum % Offset13 for
sensing condition; Sensor returns to
Adjust mode
Remote Input
•
Present sensing condition
•
Single-pulse the remote input
T
3. Return to RUN Mode
11 SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
12 Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
13 See
on page 22 for more explanation of the % Offset displayed after the Window SET method
DF-G3 Long Range Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link
www.bannerengineering.com - Tel: + 1 888 373 6767
17