![Banner DF-G1-NS-2M Installation Manual Download Page 8](http://html1.mh-extra.com/html/banner/df-g1-ns-2m/df-g1-ns-2m_installation-manual_3753860008.webp)
Method
Action
Result
SET Button
a. Present the first condition.
b. Click the SET rocker button
Display: Flashes "2Pt tch" then holds
on "1234 2nd"
Remote Input
a. Present the first condition.
b. Single-pulse the remote input.
T
3. Teach the second condition.
Method
Action
Result
SET Button
a. Present the second condition.
b. Click the SET rocker button.
TEACH Accepted
Displays alternate "PASS" and %
Minimum Difference4; Sensor returns
to Adjust mode
TEACH Not Accepted
Displays alternate "FAIL" and %
Minimum Difference4; Sensor returns
to Adjust mode
Remote Input
a. Present the second condition.
b. Single-pulse the remote input.
T
4. Return to Run mode.
Method
Action
Result
SET Button
Move the Mode switch to RUN
Display: Red - Signal Level; Green -
Threshold
Remote Input
No action is required; sensor returns to
RUN mode automatically
Dynamic TEACH
•
Teaches on-the-fly
•
Establishes a single switching threshold
•
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual
sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the
optimum level (see
Figure 3
on page 9).
4 See
Troubleshooting
on page 18 for more explanation of the % Minimum Difference displayed after the Two-Point TEACH
method.
DF-G1 Expert
™
Dual Display Fiber Amplifier