![Banner DF-G1-NS-2M Installation Manual Download Page 11](http://html1.mh-extra.com/html/banner/df-g1-ns-2m/df-g1-ns-2m_installation-manual_3753860011.webp)
Sensor positions
window thresholds
a programmable %
offset from the
presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Condition
Presented
Sensing window
center adjusted by
Manual Adjust
Output OFF
Output OFF
Output ON
Figure 4. Window SET (Light Operate shown)
Output ON and OFF conditions can be reversed using the LO/DO switch (see LO/DO Switch in
Top Panel Interface
on
page 4).
Window SET and Manual Adjust
Moves sensing window center value up or down to make adjustments
•
Slide Mode switch to ADJ to enter Adjust mode
•
Press "+" to increase; press "-" to decrease
◦
GREEN display shows the sensing window center value
◦
2 seconds after adjustment, the GREEN display will flash 3 times to confirm
•
Slide Mode switch to RUN to complete operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform a Window SET:
Note: TEACH Selection must be programmed to wind SEt (see
Program Mode
on page 6 )
1. Enter Adjust Mode
Method
Action
Result
SET Button 8
Set Mode switch to ADJ
Display: Red - Signal Level; Green -
Threshold
Remote Input 9
No action required; sensor is ready for
Window SET method
2. SET Sensing Condition
8 SET Button: 0.04 seconds
≤
"Click"
≤
0.8 seconds
9 Remote Input: 0.04 seconds
≤
T
≤
0.8 seconds
DF-G1 Expert
™
Dual Display Fiber Amplifier
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]