Push Button
0.04 seconds < "Click" < 0.8
seconds
Remote Line
0.04 seconds < T < 0.8 seconds
Result
TEACH Unacceptable
Power LED: OFF
Bar graph: #1, 3, 5, 7 alternately flash
to show failure
Sensor returns to Run mode without changing settings
Single-Point Window Set
• Sets a single ON condition that extends 12.5% above and below the taught condition
• All other conditions (lighter or darker) result in OFF output
• Sensing window size (sensitivity) is adjustable using “+” and “-” buttons (see
on page 9)
Window Set is most useful when a product may not always appear in the
same place, or when other signals may appear. Window Set designates a
sensing window, with the Output ON condition inside the window, and the
Output OFF conditions outside the window. The sensor accepts a single
sensing condition, and adds switching thresholds above and below that con-
dition to create a sensing window. Output ON and OFF conditions can be re-
versed by changing Light/Dark Operate status in Setup mode.
Window Set and Manual Adjust
Using Manual Adjust with Window Set expands or contracts the size of the
window. The lighted LEDs on the light bar separate to a greater or lesser ex-
tent to exhibit the relative sensing window size.
Sensor positions
window thresholds
± 100 counts from the
presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Taught
Condition
200 counts
Hysteresis
100 counts
Hysteresis
100 counts
Output OFF
Output OFF
Output ON
Sensing window size adjusted by
Manual Adjust
Figure 3. Single-Point Window SET and Hysteresis
(Light Operate shown)
Push Button
0.04 seconds < "Click" < 0.8 sec-
onds
Remote Line
0.04 seconds < T < 0.8 seconds
Result
Access SET Mode
• Press and hold Static button > 2
seconds
• Single-pulse remote line
T
Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Status LEDs: LO & DO alternately flashing
SET Sensing Condi-
tion
• Present sensing condition
• Double-click Static button.
• Present sensing condition.
• Double-pulse remote line
T
T
T
Window Accepted
Power LED: ON
Bar graph: 2 indicators flash together
to show Window accepted
Sensor returns to Run mode with new settings
Window Unacceptable
Power LED: OFF
Bar graph: #1, 3, 5, 7 flash
to show failure
Sensor returns to "SET Sensing condition"
D10 Expert Series with Bar Graph Display and Discrete Output
P/N 117830 Rev. F
www.bannerengineering.com - tel: 763-544-3164
5