Specifications—Reader

Supply Voltage

5 V dc to 30 V dc

10 V dc to 30 V dc with TCNM-ACBB1

Consumption

0.4 A to 0.1 A maximum

Communication Interface

Main RS232 or RS422 full duplex: 2400 bit/s to 115200 bit/s

USB: USB 2.0 Hi-Speed

Ethernet

10

: 10/100 Mbit/s

Inputs

Input 1 (External Trigger) and Input 2: Protected against short-circuits (opto-isola-

ted and polarity insensitive when connected through TCNM-ACBB1)

Outputs

2 NPN or PNP short circuit protected (opto-isolated and polarity sensitive when

connected through TCNM-ACBB1)

Optical Features

See the Instruction Manual for details

LED Safety: LED emission according to EN 62471

Imager

WVGA: 752 × 480 pixels, CMOS

1.2MP: 1280 × 960 pixels, CMOS

Construction

Aluminum

Operating Conditions

Operating Temperature

11

: 0 °C to +45 °C (+32 °F to +113 °F)

Storage Temperature: –20 °C to +70 °C (–4 °F to +158 °F)

90% maximum relative humidity (non-condensing)

Environmental Rating

IEC IP65

Other

Smart Teach button (configurable via Barcode Manager), beeper

Parameter Storage

Permanent memory (Flash)

Required Overcurrent Protection

WARNING: Electrical connections must be made by

qualified personnel in accordance with local and na-

tional electrical codes and regulations.

Overcurrent protection is required to be provided by end product application per

the supplied table.

Overcurrent protection may be provided with external fusing or via Current Limit-

ing, Class 2 Power Supply.

Supply wiring leads < 24 AWG shall not be spliced.

For additional product support, go to 

www.bannerengineering.com

.

Supply Wiring (AWG)

Required Overcurrent Protection (Amps)

20

5.0

22

3.0

24

2.0

26

1.0

28

0.8

30

0.5

Certifications

Barcode Types

1-D and stacked

2-D

POSTAL

PDF417 Standard and Mi-

cro PDF417

Code 128 (GS1-128)

Code 39 (Standard and Full

ASCII)

Code 32

MSI

Standard 2 of 5

Matrix 2 of 5

Interleaved 2 of 5

Codabar

Code 93

Pharmacode

EAN-8/13-UPC-A/E (includ-

ing Addon 2 and Addon 5)

GS1 DataBar Family

Composite Symbologies

Data Matrix ECC 200

(Standard, GS1 and Direct

Marking)

QR Code

(Standard and Direct Mark-

ing)

Micro QR Code

MAXICODE

Aztec Code

Australia Post

Royal Mail 4 State Custom-

er

Kix Code

Japan Post

PLANET

POSTNET

POSTNET (+BB)

Intelligent Mail

Swedish Post

FCC Statement

Modifications or changes to this equipment without the expressed written approval of Banner Engineering could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this

device must accept any interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio fre-

quency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in

a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

PC Requirements—

Barcode Manager

Administrative rights are required to install the Barcode Manager software.

Operating System

Microsoft

®

 Windows

®

 operating system version XP SP3

12

, 7, 8, or 10

13

Barcode Manager does not currently support Windows Embedded (often used in

industrial PCs and/or PLCs)

System Type

32-bit or 64-bit

Hard Drive Space

2 GB hard disk for 64-bit machines; 1 GB hard disk for 32-bit machines

Memory (RAM)

1 GB RAM

Processor

2.00 GHz or faster microprocessor

Screen Resolution

One 19-inch or larger monitor, optimized for 1280×1024 resolution

Third-Party Software

Web Browser: Google Chrome, Mozilla Firefox, Microsoft Internet Explorer, Opera,

etc.

Connection

100 Base-T Ethernet

10

The Ethernet interface supports application protocols: TCP/IP, EtherNet/lP, Modbus TCP

11

High ambient temperature applications should use a metal mounting bracket for heat dissipation.

12

Windows XP is not compatible with ABR 3000 USB models.

13

Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries.

ABR 3000

 

 

P/N 207636 Rev. A

www.bannerengineering.com - Tel: +1-763-544-3164

7

Summary of Contents for ABR 3000 series

Page 1: ...Serial Ethernet 1D ABR3106 WSU2 1 2 MP 1280 960 pixels 6 mm manual focus Serial USB 1D and 2D ABR3106 WSE2 Serial Ethernet 1D and 2D ABR3106 WSU1 Serial USB 1D ABR3106 WSE1 Serial Ethernet 1D ABR3106...

Page 2: ...mm to 80 mm 1 2 in to 3 1 in 25 mm to 70 mm 1 0 in to 2 8 in 70 56 mm 2 2 in 60 mm to 125 mm 2 4 in to 4 9 in 45 mm to 100 mm 1 8 in to 3 9 in 125 95 mm 3 7 in 95 mm to 155 mm 3 7 in to 6 1 in 65 mm...

Page 3: ...vides access to the following modes Icon Description Test Mode includes bar graph visualization to check static reading performance Focus Aim turns on the laser aiming cross to aim the reader at the t...

Page 4: ...D stops blinking the ABR beeps once and exits Setup mode 3 If the calibration cannot be reached after a timeout of about 5 five seconds ABR exits without saving the parameters to memory the Setup LED...

Page 5: ...n then on the Start menu click Control Panel or search for Control Panel b In Control Panel click Network and Internet then click Network and Sharing Center and then click Change adapter settings c Ri...

Page 6: ...on the device For new devices the only saved configuration is the Default configuration 2 Click OK The device enters continuous mode and begins acquiring images 3 Place the application code in front...

Page 7: ...ark ing Micro QR Code MAXICODE Aztec Code Australia Post Royal Mail 4 State Custom er Kix Code Japan Post PLANET POSTNET POSTNET BB Intelligent Mail Swedish Post FCC Statement Modifications or changes...

Page 8: ...ty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXT...

Reviews: