4
SPECIFICATIONS
Pipe Size
1" Full Port
Fittings
Flange Clamps/NPT Pipe Fittings
Pressure
150 PSI or 10.3 bar working pressure @ 70°F
Operating Temperature Range
10° to 130°F (-12° to 54°C)
Accuracy
+/-1% of reading from 100% to 10% of full scale
+/-3% of reading from 10% to 10% of full scale to cut off=> 2% to 10%
Flow Range
Minimum
2.3 GPM & 8.7 LPM
Maximum
110 GPM & 416.4 LPM
Materials
Body
Glass-filled polypropylene
Electrodes
316 stainless steel
Electronics Housing
Die cast aluminum, powder-coated
Display Cover
Polyethylene
Display
Rate
Digits
6
Units
Gallons/Minute
Liters/Minute
Power
6 AA alkaline cells, replaceable Life: 1 year with meter in use; 3 years dry
10-30 Vdc @ 60 mA max (15 mA average) Note: Using an unregulated power
supply >18 Vdc may damage the meter due to AC line input voltage fluctuation.
Pulse Output
Signal
Current sinking pulse, opto isolate, 32 Vdc max at 10 mA max
Standard Pulse Rate
1 unit/pulse out, pulse width of 10 ms depending on unit selection
High Frequency
80 Pulse per unit, pulse width 1.1 ms, min-max frequency, 3-150 HZ
Empty Pipe Detection
Hardware/software, conductivity-based
Conductivity
>20 microSiemens
Environmental
NEMA 4X standard; -40° to 176°F (-40° to 80° C) storage
Electrical Connection
5 pin male circular connector, mates to industry standard cable (20ft/6m)
* Specifications subject to change • Please consult our website for current data (www.banjocorp.com)
SPECIFICATIONS*