DISASSEMBLY INSTRUCTIONS:

Remove the 10 body screws (12720), lock washers (V07018) and 

nuts (V07019) from the pump assembly. Remove the body from the 

pump assembly.

Remove the check valve (12705) from the volute (12702A/13702). 

2A

1

Remove the check valve (12705) from the volute (13702). Remove 

the one upper volute screw (12900) and the two smaller volute 

screws (12725) from the volute. Remove the volute from the 

remaining pump assembly.

2B

Remove the impeller bolt (12765A) from the  

impeller (12771A/12772). Remove the impeller bolt gasket 

(12774VA) from the impeller.

3

4A: 

Screw the supplied 7/16-14 hex head cap screw into the 

impeller snout. As the bolt is tightened the impeller will be pried off 

of the shaft of the drive unit. Remove the 7/16-14 screw once the 

impeller has been removed from the drive unit. 

4B:

 If the pump im-

peller is going to be reused the ceramic seal half (12713) should be 

removed from the impeller at this time. The impeller key (12902A) 

located behind the ceramic seal half should be replaced at this time 

also.

Remove the four bracket screws (12715A), rear bracket washers 

(12901), and screw head O-rings (12717) from the rear bracket using 

a ½″ socket. With the four bracket screws removed, the rear bracket 

can now be removed from the drive unit.

4A

4B

5

Summary of Contents for 200P6PROE

Page 1: ...ING POLY CENTRIFUGAL PUMPS INSTRUCTION MANUAL BANJO CORPORATION A Unit of IDEX Corporation 150 Banjo Drive Crawfordsville IN 47933 U S A banjocorp com Telephone 765 362 7367 B A N J O C O R P C O M 1...

Page 2: ...er Make certain that all hose and pipe connections are air tight An air leak in the suction line may prevent priming and will reduce the performance of the pump Always place the pump as close to the l...

Page 3: ...0 11 23 34 46 57 69 Pressure PSI 0 5 10 15 20 25 30 Flow GPM 300 285 240 190 145 85 15 Note Curve based on water and pump spinning at 3450 RPM PERFORMANCE CHART 3450 RPM Head flow curve for the follo...

Page 4: ...eller bolt gasket 12774VA from the impeller 3 4A Screw the supplied 7 16 14 hex head cap screw into the impeller snout As the bolt is tightened the impeller will be pried off of the shaft of the drive...

Page 5: ...the drive unit shaft The slinger should be slid all the way back on the shaft of the drive unit so that the slinger covers the step on the drive unit shaft as shown Place the seal O ring 12710 behind...

Page 6: ...55 in lbs 8 Install the O ring segment 12754 onto the rear bracket as shown 9 10 Install volute 12702A 13702 onto rear bracket using the three volute screws 12900 12725 Tighten the 3 screws to 8 12 i...

Page 7: ...orp com for more information ASSEMBLY INSTRUCTIONS Place the pump body O ring 12719A around the outside flange of the rear bracket The O ring may be sparingly lubricated with silicone to ease installa...

Reviews: