background image

C O N N E C T   W I T H   C O N F I D E N C E

2

OPERATION NOTICE

Do not operate the gas engine (if so equipped)  

until you have put oil in the engine. Do not run  

the pump dry. Serious damage to the mechanical 

seal or complete failure of the mechanical seal can 

result from running the pump dry. Always fill the 

pump with water or the fluid being pumped before 

starting the drive unit.

WARNING! DO NOT USE WITH 

FLAMMABLE LIQUIDS.

Do not use flammable liquids. This pump is not 

designed or produced to pump flammable liquids of 

any kind. Failure to follow this warning can result in 

explosion, serious bodily injury or death. 

OVERVIEW

Read these instructions and the instructions covering operation of the pump drive unit. 

The gas engine (if so equipped) is shipped with no oil. Consult your owners manual for specific oil recommendations,

 

maintenance procedures, schedules, and troubleshooting. The maximum angle of operation for gas engine drive units is 

25° in all directions. For engine warranty service contact your local engine dealer.

Make certain that all hose and pipe connections are air tight. An air leak in the suction line may prevent priming and will 

reduce the performance of the pump. 

Always place the pump as close to the liquid to be pumped  as possible. Keep the suction line short and with few bends. 

Keep the pump and engine on a level foundation. A poor foundation and a heavy suction hose (made heavier when 

“primed” full of liquid) could result in a pump “down the hole”. It is not necessary to drain the pump body after use, unless 

there is a danger of freezing.

There are no points on the pump that need lubrication. The pump seal is cooled and lubricated by the fluid being pumped. 

When pumping dirty water or liquids containing solids, always use a pump strainer on the end of the suction line. Note: 

Engine warranty service available at authorized Briggs & Stratton

®

 and Honda

®

 dealers. 

WARNINGS

STORAGE NOTICE

There are important instructions regarding the 

preparation of the engine for long periods without 

use, (reference the engine instruction manual). 

Before long periods of storage, the pump should 

be flushed with clean water and drained. Leave all 

plugs (fill and drain) out of the pump. Always store 

the pump unit in a heated and dry building.

Summary of Contents for 200P6PROE

Page 1: ...ING POLY CENTRIFUGAL PUMPS INSTRUCTION MANUAL BANJO CORPORATION A Unit of IDEX Corporation 150 Banjo Drive Crawfordsville IN 47933 U S A banjocorp com Telephone 765 362 7367 B A N J O C O R P C O M 1...

Page 2: ...er Make certain that all hose and pipe connections are air tight An air leak in the suction line may prevent priming and will reduce the performance of the pump Always place the pump as close to the l...

Page 3: ...0 11 23 34 46 57 69 Pressure PSI 0 5 10 15 20 25 30 Flow GPM 300 285 240 190 145 85 15 Note Curve based on water and pump spinning at 3450 RPM PERFORMANCE CHART 3450 RPM Head flow curve for the follo...

Page 4: ...eller bolt gasket 12774VA from the impeller 3 4A Screw the supplied 7 16 14 hex head cap screw into the impeller snout As the bolt is tightened the impeller will be pried off of the shaft of the drive...

Page 5: ...the drive unit shaft The slinger should be slid all the way back on the shaft of the drive unit so that the slinger covers the step on the drive unit shaft as shown Place the seal O ring 12710 behind...

Page 6: ...55 in lbs 8 Install the O ring segment 12754 onto the rear bracket as shown 9 10 Install volute 12702A 13702 onto rear bracket using the three volute screws 12900 12725 Tighten the 3 screws to 8 12 i...

Page 7: ...orp com for more information ASSEMBLY INSTRUCTIONS Place the pump body O ring 12719A around the outside flange of the rear bracket The O ring may be sparingly lubricated with silicone to ease installa...