background image

6

3.2Display Interface Introduction

11-CH1 Parameters

12- CH2 Parameters

13-Wave Display

14-Current Channel Output State

15-Function list ofSoftkey

16-Phase angle between CH1 and CH2

3.3 Button function Introduction

name

Introduction

Function softkey

Function softkey can activate the corresponding function on the screen

Enter main interface, or set waveform of currentchannel

Fast switch between measurement mode interface and main interface

Fast switch betweenmodulation mode interface and main interface

Fast switch between system setting interface and main interface

In main interface, press it to control output of CH1 and CH2 in the same time; in

modulation mode interface, press it to control ON/OFF

When setting parameter

press it to move cursor to set step value.

Press it to enter CH1 channel, and press it again to control output of CH1, You can keep

pressing for more than 1sto set CH1 into theprimary channel.

Press it to enter CH2 channel, and press it again to control output of CH2, you can keep

pressing for more than 1s to set CH2 into the primary channel.

Summary of Contents for JDS2900 Series

Page 1: ...OPERATING MANUAL JDS2900 Series Digital Control Dual channel DDS Signal Generator Rev1 0 MAY 2017...

Page 2: ...ent Introduction 6 3 1 Front Panel Introduction 6 3 2 Rear Panel Introduction 6 3 3 Display Interface Introduction 7 3 4 Button fuction Introduction 6 4 Operation Introduction 8 4 1 Introduction of Ma...

Page 3: ...amage or defect or if the instrument does not operate properly or pass the electrical and mechanical tests you can contact us or reseller 2 Summary 2 1 Brief Introduction JDS2900 series DDS signal gen...

Page 4: ...0S 30nS 4000S 30nS 4000S Mininum Frequency resolution 0 01 Hz 0 00000001Hz Frequency accuracy 20ppm Frequency stability 1ppm 3h Waveform Characteristics Waveform Sine Square Triangle Pulse duty cycle...

Page 5: ...9 99V 9 99V 2 5V 2 5V 0 25V 0 25V Offset resolution 0 01 V Phase characteristics Phase adjusting range 0 359 9 Phase resolution 0 1 TTL COMS Output Low level 0 3V High level 1V 10V Level rise fall ti...

Page 6: ...on 00 Arbitrary wave quantity 1 to 60 totally 60 groups default set 15 groups Interface Interface mode USB to serial interface Extension interface There is serial interface of TTL level mode to be con...

Page 7: ...5 3 Instrument Introduction 3 1 Front Panel Introduction...

Page 8: ...interface Fast switch betweenmodulation mode interface and main interface Fast switch between system setting interface and main interface In main interface press it to control output of CH1 and CH2 in...

Page 9: ...oftkey for more than 1 second to change frequency unit 4 1 5 Other parameters setting aresame as 4 1 14 Keep pressing OFFS DUTY and PHAS to Initialize to default values 4 2 Introduction of measurement...

Page 10: ...ore and delate press corresponding softkey 4 4 2 Sync When sync CH1 is the object of operation CH2 parameter will be changed with the changes of CH1 parameter When the sync item is selected you can pr...

Reviews: