Test, adjustment and configuration after repair
Configure PDP for B&O menu.
Test and adjustment after replacement of module(s).
WARNING
Burn-in on the PDP might occur when displaying a non-moving picture for more
than app. 30 minutes.
Test and adjustment
Test and adjustment after replacement of module(s) must be executed after any
repair on the PDP.
Configure PDP for B&O menu
The D module must be configured to work with Bang & Olufsen features.
1. Please refer to illustration for:
- placement of buttons on Plasma panel and NN remote control.
- CAT Panel menu & CD mode.
2. Remove the black self-adhesive tape.
3. Switch BeoVision 5-42 on.
4. Switch Plasma panel on.
Press the button marked
“A”
.
The Plasma led lights green.
5. Enter Service mode.
Press and hold the button
“B”
and at the same time press button
“C”
3 times
within 1 seconds.
6. Access to CD Mode in the CAT Panel menu.
Use the arrow buttons to select CD Mode.
Press the button
“D”
for 5 seconds.
7. CD menu.
8. Check Memory Address and Data in Memory data change.
Use the arrow buttons to find the required memory address in Memory data change.
First address code is set using the left/right arrow buttons.
Second address code is set using the up/down arrow buttons.
9. Check the Address and Data.
Address
Data
10. Change data in Memory data change.
Use the volume buttons (+/-) to change the Data value.
Change the data to the values below.
Data for Plasma Panel
Address
Data
00
10
8A
10
00
01
8B
01
00
01
8C
01
00
10
8F
10
1.12 Test, adjustment and configuration after repair, English
00
10
8A
10
00
01
8B
01
00
01
8C
01
00
10
8F
10