2.4 Fault flow chart
Fault symptom:
- Fault in voltages
Possible causes:
- PCB6, SMPS
- Connections
Measure mains supply
Fuse F0 OK?
Measure connection
to Socket, PCB
OK?
Re-establish
connection
Measure 2V, -2V,
6V 5V_SB
OK?
Measure all
connections in BS4
are all right
Change
PCB6, SMPS
Fault symptom:
- Front glass does not close
Possible causes:
- Bright light shining on the product
- PCB3, Magic
Use menu to change
sensitivity of the door
censors
OK?
Lift the front glass a
little
Push “Load”
Front glass opens
BS4 is placed in bright
light?
No
Yes
Measure connections
or replace PCB3,
Magic
Move BS4 to another
place
OK?