How to service
Front line service
Both the Master and the Socket Unit has been developed for simple module
exchange to follow the On-site service strategy. Module exchange is possible On-
site, at the dealer or in the service workshop whatever is most convenient in each
case. For On-site service a Back-up suitcase must be used.
Module exchange is the recommended way to perform service, due to the fact
that most of the modules are multi layer based, and most of the circuits are on a
single main PCB.
An electrical fault symptom can be removed during one visit to the customers
home if you bring a BeoCenter 2 Back-up suitcase with you.
Is it a mechanical symptom, the particular part must be brought with you
separately.
The Socket Unit and the Master Unit must be connected when testing, because
the Socket Unit contains the power supply.
Service documentation
Service Documentation for the BeoCenter 2 will be a “Service Center repair
guide” with part nr. for the Back Up suitcase, electrical and mechanical parts,
User’s guides etc.
Converting mains voltage supply
The Master Unit has only one variant for all markets.
The Socket Unit has separate type nos. for each market, due to country approvals.
The mains voltage is determined by the type nos. of the Socket Unit, there are
only two internal mains voltage settings (a jumper) on the SMPS, 100/120V and
230/240V AC. (J10, when mounted = 100/120V)
Use the ServiceTool to reprogramme the DVD region code and tuner setup.
The only variant on the Master Unit : 2801
The variants on the Socket Unit :
Variant
Area
Region
2811 :
EU2
DVD region 2
2812 :
EU3
DVD region 3
2813 :
EU4
DVD region 3
2814 :
EU5
DVD region 4
2815 :
GB2
DVD region 2
2816 :
GB3
DVD region 3
2817 :
US4
DVD region 1
2818 :
US4
DVD region 4
2819 :
JP2
DVD region 2
2820 :
AU4
DVD region 4
2821 :
TW3
DVD region 3
2822 :
KR3
DVD region 3
2823 :
LA4
DVD region 4
How to service, English 1.1
DVD Region setup
First time the Master Unit is connected to the Socket Unit, and powered, the DVD
region code is set, and stored.
Summary of Contents for BeoCenter 2
Page 6: ...3 1 Overall block diagram Overall block diagram 3 1 3 1 Overall block diagram ...
Page 7: ...3 2 Wiring diagram Wiring diagram 3 2 3 2 Wiring diagram ...
Page 29: ...Replace Keyboard left Replace Keyboard left 1 3 5 Socket Unit 2 180º 4 6 1 ...
Page 30: ...Replace Keyboard right Replace Keyboard right 1 4 Socket Unit 5 2 180º 3 6 2 ...
Page 46: ...6 18 ...
Page 53: ......
Page 54: ...Bang Olufsen DK 7600 Struer Denmark Phone 45 96 84 11 22 Fax 45 97 85 39 11 3538001 11 03 ...