Kaskode One Rev 1.1
17
The desired input capacitance is enabled with each switch position. Combinations of capacitance
are also enabled by moving multiple switch positions to “ON”
. The table below shows all 15 input
capacitance combinations available on the Kaskode One to dial the best performance with any
cartridge.
Table 1: Input Capacitance for each switch
Table 2: Input Capacitance Combinations
The figure below shows how switches S2/S5 should be set for 150pF of input capacitance.
S2/S5 Capacitance Loading Table
Position ON
Capacitance
1,2,3,4
425pF
1,2,3
375pF
1,2,4
350pF
1,3,4
325pF
1,2
300pF
1,3
275pF
1,4
250pF
2,3,4
225pF
1
200pF
2,3
175pF
2,4
150pF
3,4
125pF
2
100pF
3
75pF
4
50pF
S2/S5 Capacitance Loading Table
Position ON
Capacitance
1
200pF
2
100pF
3
75pF
4
50pF
1
2
3
4
ON
OFF
Figure 10: S2/S5 setting for 150pF