Switches S2 and S5 are used to set the capacitive loading (S2 for the Right channel and S5 for the
Left channel) by moving the switch positions 1-
4 indicated to the “ON” position.
Note:
Orientation of S2 and S5 are rotated 180
º
from each other. Be sure to set both S2
and S5 identically.
Figure 9: Location of S2 and S5 switches for setting the input capacitance