Technical data
4.4.5 Vibration and shock
The following table provides an overview of the maximum vibrations and shock values of the complete system.
Limitations are possible due to individual components.
Vibration
Panel PC
Operation
1)
Storage
1)3)
Transport
1)3)
Continuous
Periodic
With CFast card
2 to 9 Hz:
1.75 mm amplitude
9 to 200 Hz: 0.5 g
2 to 9 Hz:
3.5 mm amplitude
9 to 200 Hz: 1 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
Shock
Panel PC
Operation
2)
Storage
2)3)
Transport
2)3)
With CFast card
15 g, 11 ms
30 g, 6 ms
30 g, 6 ms
1)
Testing is performed per EN 60068-2-6.
2)
Testing is performed per EN 60068-2-27.
3)
The specification refers to a device in its original packaging.
The specifications for vibration and shock
during operation
apply equally to installation with retaining clips and
using a VESA bracket.
Panel PC 1200 panel mount device User's manual V1.08
37