5. Model numbers
5.1 System units
Model number
Short description
Note
5PC600.SX01-00
System 1 PCI
APC620 system unit 1 half size PCI slot, connection for 2 x RS232, 2 x USB 2.0,
Short Display Link, 2 x ETH 10/100, AC97 sound, PS/2 keyboard/mouse; UPS module
1)
;
24 VDC (order 0TB103.9 screw clamp or 0TB103.91 cage clamp terminals separately).
1) Slot only available on system units with revision H0 or later.
See page 46
5PC600.SX02-00
System 2 PCI, 1 disk drive slot, 1 AP Link slot
APC620 system unit 2 half size PCI slots, 1 drive slot, 1 slot for Automation Panel link
transmitter; connections for 2 x RS232, 2 x USB 2.0, Short Display Link, 2 x ETH 10/100,
AC97 sound, PS/2 keyboard/mouse, UPS module
2)
;
24 VDC (order 0TB103.9 screw clamp or 0TB103.91 cage clamp terminals separately).
2) Slot only available on system units with revision G0 or later.
See page 52
5PC600.SX02-01
System 2 PCI, 1 disk drive slot
APC620 system unit 2 half size PCI slots, 1 drive slot; connections for 2 x RS232, 2 x USB
2.0, Short Display Link, 2 x ETH 10/100, AC97 sound, PS/2 keyboard/mouse, UPS module
1)
; 24 VDC (0TB103.9 screw clamp or 0TB103.91 cage clamp sold separately).
See page 52
5PC600.SF03-00
System 3 PCI, 1 disk drive, 1 AP Link slot
APC620 system unit, 3 full-size PCI slots; 1 slot for Automation Panel link transmitter; 1 drive
slot; Smart Display Link / DVI / monitor, connections for 2 x RS232, 2 x USB 2.0, 2 x ETH
10/100, AC97 sound, PS/2 keyboard/mouse; 24 VDC (0TB103.9 screw clamp or 0TB103.91
cage clamp sold separately).
See page 58
5PC600.SX05-00
System 5 PCI, 2 disk drive slots, 1 AP Link slot
APC620 system unit 5 half size PCI slots, 2 drive slot; 1 slot for Automation Panel Link
Transmitter; connections for 2 x RS232, 2 x USB 2.0, Short Display Link, 2 x ETH 10/100,
AC97 sound, PS/2 keyboard/mouse, UPS module
3)
; 24 VDC (0TB103.9 screw clamp or
0TB103.91 cage clamp sold separately).
3) Slot only available on system units with revision F0 or later.
See page 63
5PC600.SX05-01
System 5 PCI, 2 disk drive slots
APC620 system unit 5 half size PCI slots, 2 drive slots; connections for 2 x RS232, 2 x USB
2.0, Short Display Link, 2 x ETH 10/100, AC97 sound, PS/2 keyboard/mouse, UPS module
3)
; 24 VDC (0TB103.9 screw clamp or 0TB103.91 cage clamp sold separately).
See page 63
5PC600.SE00-00
APC620e System SDL EPL X2X CAN 512kB
APC620 embedded system unit, connections for 2x RS232, 4x USB 2.0, Smart Display Link,
1x ETH 10/100, 1x POWERLINK, 1x CAN, 1x X2X, UPS module, 512kB SRAM; (0TB103.9
screw clamp or 0TB103.91 cage clamp sold separately).
See page 69
5PC600.SE00-01
APC620e System CRT EPL X2X CAN 512KB
APC620 embedded system unit, connections for 2x RS232, 4x USB 2.0, CRT, 1x ETH
10/100, 1x POWERLINK, 1x CAN, 1x X2X, UPS module, 512kB SRAM; (0TB103.9 screw
clamp or 0TB103.91 cage clamp sold separately).
See page 69
5PC600.SE00-02
APC620e System SDL EPL X2X CAN 1MB
APC620 embedded system unit, connections for 2x RS232, 4x USB 2.0, Smart Display Link,
1x ETH 10/100, 1x POWERLINK, 1x CAN, 1x X2X, UPS module, 1MB SRAM; (0TB103.9
screw clamp or 0TB103.91 cage clamp sold separately).
See page 69
Table 4: Model numbers - system units
Summary of Contents for Automation PC 620
Page 2: ...2 Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...
Page 4: ...4 Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...
Page 6: ...6 Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...
Page 568: ...568 Appendix A Glossary Automation PC 620 with 945GME N270 CPU board User s Manual V 1 10 ...