Programming guidelines
136
ACOPOSinverter P84 User's Manual 2.10
2.8.6.4 With graphics terminal: Internal inverter states and values
Name/Description
[Alarm group]
(ALGr)
Current alarm group numbers
[HMI Freq Ref.]
(LFr)
in Hz. Frequency reference via the graphic display terminal (can be activated if the function has been configured).
[Int. Ref. PID]
(rPI)
As process value. PID reference via the graphic display terminal (can be activated if the function has been configured).
[Ref. Torq. HMI]
(Ltr)
As % of nominal torque. Torque reference via graphic display terminal.
[Multiplic coeff]
(MFr)
in % (can be called if
[Multiplier -]
(MA2,MA3)
,
see "CONFIG REF (OAI-)" on page 203
[Reference frequency]
(FrH)
In Hz
[Ref. Torq.]
(trr)
In % of nominal torque (can be called if the function was configured)
[Motor frequency]
(rFr)
In Hz
[Meas. MotFreq. pref.]
(MMF)
In Hz: The measured motor speed is displayed if an encoder card is inserted; otherwise, 0 is displayed.
[Motor current]
(LCr)
In A
Mean Speed ENA]
(OFF)
In Hz: The parameter can be called if
[ENA System]
(EnA)
=
[Yes]
(YES)
(
see "Drive parameters (EnA - rAP)" on page 160
)
[Speed.]
(SPd)
In rpm
[Motor volt.]
(UOP)
In V
[Motor power]
(OPr)
As % of nominal power
[Motor torque]
(Otr)
As % of nominal torque
[Line voltage]
(ULn)
In V. line voltage from the point of view of the DC bus with the motor stopped or running.
[Therm. FU state]
(tHr)
As %
[Therm. FU state]
(tHd)
As %
[Th. brake val. state]
(tHb)
As % (can only be called on inverters with high nominal current)
[Consumption]
(APH)
In Wh, kWh or MWh (cumulative consumption)
[Motor run time]
(rtH)
In seconds, minutes or hours (motor duty cycle)
[Drive operating time]
(PtH)
In seconds, minutes or hours (inverter duty cycle).
[Temp AI IGBT time]
(tAC)
In seconds (period in which alarm "IGBT-Temperature" was active).
[ Ref. PID]
(rPC)
As process value (can be called if the PID function has been configured)
[PID feedback]
(rPF)
As process value (can be called if the PID function has been configured)
[PID error]
(rPE)
As process value (can be called if the PID function has been configured)
[PID out]
(rPO)
In Hz (can be called if the PID function has been configured)
[act. configuration]
(CnFS)
Active configuration [Config no. 0, 1 or 2]
[act. parameter set]
(CFPS)
[Set no. 1, 2 or 3] (access possible if the parameter switch has been activated (
see "PARAMETER SWITCH (MLP-)" on page
[ALARMS]
(ALr-)
List of currently configured alarms. In the event of an alarm, a check mark appears.
[OTHER STATE]
(SSt-)
List of secondary states:
•
[Magn motor active]
(FLX)
: In-motor magnetization
•
[HSP err.]
(FLA)
: High frequency attained
•
[Alarm PTC1]
(PtC1)
: LI6 = PTC sensor alarm
•
[Load relax.]
(AnA)
: Alarm for a lag error
•
[Alarm PTC2]
(PtC2)
: Alarm PTC sensor 2
•
[Set 1 active]
(CFP1)
: Parameter set 1 active
•
[Alarm LI6=PTC]
(PtC3)
: Alarm PTC sensor LI6=PTC
•
[Set 2 active]
(CFP2)
: Parameter set 2 active
•
[Quick stop]
(FSt)
: Quick stop
•
[Set 3 active]
(CFP3)
: Parameter set 3 active
•
[Thresh. I err.]
(CtA)
: Current threshold value reached
(
[Current threshold]
(Ctd)
)
•
[Brake active]
(brS)
: Drive braking
•
[Thresh. Freq. err.]
(FtA)
: Frequency threshold is
reached (
[F.-Thresh. Mot]
(Ftd)
)
•
[Load DC Bus]
(dbL)
: Load of the DC bus
•
[Thresh. Freq 2 err.]
(F2A)
: 2. Frequency threshold
•
Achieved (
[Freq. threshold 2]
(F2d)
)
•
[Forward]
(MFrd)
: Motor rotating in the forward direction
(right)
•
[FRH err.]
(SrA)
: Frequency reference reached
•
[Reverse]
(MrrS)
: Motor rotating in the reverse direction
(left)
•
[Th Status Motor err]
(tSA)
: Motor thermal state 1
reached
•
[Alarm high torque]
(ttHA)
: Motor torque above upper
threshold
[Torque thd. high]
(ttH)
•
[Ext. fault]
(EtF)
: Alarm for an external fault
•
[Alarm low torque]
(ttLA)
: Motor torque below lower
threshold
[Torque thd. low]
(ttL)
•
[Auto]
(AUtO)
: Automatic restart
•
[Remote]
(FtL)
: Control in online mode
•
[Autotuning]
(tUn)
: Autotuning
•
[Undervoltage]
(USA)
: Alarm for an undervoltage
•
[Config.1]
(CnF1)
: Configuration 1 active
•
[Config.2]
(CnF2)
: Configuration 2 active
Summary of Contents for ACOPOSinverter P84
Page 2: ......
Page 391: ...Accessories ACOPOSinverter P84 User s Manual 2 10 391 4 7 2 Installation 8I0XF084 020 1...
Page 392: ...Accessories 392 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 030 1...
Page 393: ...Accessories ACOPOSinverter P84 User s Manual 2 10 393 8I0XF084 040 1...
Page 394: ...Accessories 394 ACOPOSinverter P84 User s Manual 2 10 8I0XF084 050 1...
Page 395: ...Accessories ACOPOSinverter P84 User s Manual 2 10 395 8I0XF084 0x0 1...
Page 400: ...Accessories 400 ACOPOSinverter P84 User s Manual 2 10...