background image

Summary of Contents for AGN6500

Page 1: ......

Page 2: ... with foot Lock Nut Lock Nut Flat Washer Frame Frame crossbar Screw 1 in Engine Switch AC Breaker DC Breaker Key Starter Fuel Tank Oil Drainage Bolt Fuel Cap Choke Lever Fuel Valve Oil Light Air Filter Recoil Starter Grip Carburetor Drain Screw Fig 1 Fig 5 Fig 3 Fig 2 Fig 4 ...

Page 3: ...3 3 Fuel Tank Fuel Cap Extension Cord Oil Cap Dipstick Oil Cap Dipstick Oil Fill Hole Oil Fill Hole 108 mm 4 1 4 in 16 mm 5 8 in 6 mm 1 4 in Fig 7 Fig 6 Fig 10 Fig 11 Fig 8 Fig 9 ...

Page 4: ...ments Air Filter Cover Bolt Bolt Recoil Starter Grip Twist lock Receptacle Extension Cord Twist lock Plug Choke Lever To Run Choke open To Start Choke closed OFF ON Fuel Valve Fuel Valve Filter Filter Fig 17 Fig 13 Fig 14 Fig 15 Fig 16 Fig 12 ...

Page 5: ...ose fuel valve and restrain the unit from moving before transporting in a vehicle Ŷ Allow engine to cool for five minutes before refueling Ŷ To reduce the risk of fire and burn injury handle fuel with care It is highly flammable Ŷ Do not smoke while handling fuel Ŷ Store fuel in a container approved for unleaded fuel Ŷ Position the unit on level ground stop engine and allow to cool before refuelin...

Page 6: ...tand completely the operator s manual If you do not understand the warnings and instructions in the operator s manual do not use this product Call your nearest authorised service centre for assistance WARNING The operation of any products can result in foreign objects being thrown into your eyes which can result in severe eye damage Before beginning power tool operation always wear safety goggles ...

Page 7: ...l Surge Starting Watts CD Player 100 0 Space Heater 1800 0 Drill 1 2 HP 600 300 Light Bulb 75 0 2575 Total Running Watts 300 Surge Watts Total Continuous Running Watts 2575 Plus Additional Surge Watts 300 Equals Total Generator Output Required to start all items simultaneously 2875 POWER MANAGEMENT To prolong the life of the generator and attached devices it is important to take care when adding e...

Page 8: ...p protect against electrical shock Consult with a local electrician for grounding requirements in your area OIL LIGHT The oil light is an indicator for the oil level When the oil level is too low the oil light will flash in red OIL DRAINAGE BOLT When changing the engine oil the oil drainage bolt is loosened to allow old engine oil to be drained OIL CAP DIPSTICK Remove the oil fill cap to check and...

Page 9: ...the following items 2 legs with rubber feet 6 flat washers 6 lock nuts 4 screws 51 mm 2 in 2 screws 25 mm 1 in Ŷ Raise the front end of the generator where the engine is located high enough to gain access to the frame bottom securely position props underneath to support Ŷ Position a leg over the holes on each side of the frame support Ŷ Insert each 51 mm 2 in screw through a flat washer and insert...

Page 10: ...ty with tools to make you careless Remember that a careless fraction of a second is sufficient to inflict serious injury WARNING Do not use any attachments or accessories not recommended by the manufacturer of this product The use of attachments or accessories not recommended can result in serious personal injury APPLICATIONS This generator is designed to supply electrical power for operating comp...

Page 11: ...nd hold it until the engine has fully stopped The removable control panel has two 240V 15A sockets Use only with RDEC25 accessory cord Do not exceed separation length of 22 9 m 75 ft or a combination of three RDEC25 accessory cords GenSmart MONITORING SYSTEM The GenSmart monitoring system displays wattage voltage hertz and hours To cycle through each display press and release the select reset butt...

Page 12: ...p dipstick NOTE Used oil should be disposed of at an approved disposal site See your local oil retailer for more information FUEL FILTER The fuel filter prevents dirt and water that may have gotten into the fuel tank from entering the carburetor If the engine has not been run for a long time the fuel filter should be replaced before use Ŷ Drain the fuel tank into suitable container Ŷ Squeeze the e...

Page 13: ... fuel to drain completely into the container Ŷ Retighten the drain screw NOTE After draining the fuel tank and carburetor start the engine and allow it to run until the unit runs out of fuel Consult hazardous waste management guidelines in your area for the proper way to dispose of used fuel TRANSPORTING Ŷ Turn engine switch OFF O Ŷ Close the fuel valve Ŷ Make sure engine and exhaust of unit is co...

Page 14: ...ated to extend storage life For recommendations contact your nearest authorised service centre MAINTENANCE SCHEDULE Before each use After 1st month or 20 hours of operation Every 3 months or 50 hours of operation Every 6 months or 100 hours of operation Every year or after 300 hours of operation Check Engine Oil Ŷ Change Engine Oil Ŷ Ŷ Check Air Filter Ŷ Clean Air Filter Ŷ Change Air Filter Ŷ Repl...

Page 15: ...er is OFF Item plugged in is defective Turn ON the AC circuit breaker Try a different item Generator makes a spark knock or pinging noise An occasional light knocking or pinging underheavyloadisnotacause for concern However if the knocking or pinging occurs under normal load at a steady engine speed the problem may be with the brand of unleaded fuel being used Switch to a different brand of unlead...

Page 16: ...ING DIAGRAM 7KLV VLQJOH SKDVH JHQHUDWRU LV WWHG ZLWK D HG 5HVLGXDO XUUHQW HDUWK OHDNDJH HYLFH ZLWK ZLQGLQJ FRQQHFWHG DV VKRZQ LQ WKH following wiring diagram Generator Residual Current Device Outlet Frame A N E ...

Page 17: ...17 17 WIRING DIAGRAM ...

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: